A fast thermal desorption unit for micro thermal desorption tubes, Part II: Method development and validation for explosives and chemical warfare agent simulants

A thermal desorption FF-TG-GC/MS method with a cycle time of just 164s including cryofocusing, thermal desorption, analyte separation and system cool down was developed for the analysis of ten explosives and six chemical warfare agent (CWA) simulants. Sampling was carried out both in liquid and gaseous form using micro thermal desorption tubes (μTD-tubes, 1.4mm I.D., 10mg Tenax TA). In addition to the desorption conditions, the effects of deactivated μTD-tubes, the spatial temperature gradient along the separation column and additional cryofocusing to refocus the analytes were evaluated. Limits of detection between 0.17 and 9.18ng/μL and R<sup>2</sup> values ≥0.983 for calibration curves (with the exception of PETN) were obtained. Relative standard deviations of mainly <15% were achieved for within day repeatability. The fluctuations in the peak areas were mostly below 20% with between-day repeatability measured across three days.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2024-11-23
DOI
https://doi.org/10.1016/j.chroma.2024.465537
Citations
2
Primary Topic
Energetic Materials and Combustion
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fast thermal desorption unit for micro thermal desorption tubes, Part II: Method development and validation for explosives and chemical warfare agent simulants

Peter Boeker, Miriam D. Chopra, Florian Alex Menger, Matthias Wüst et al.
2 citations
Journal of Chromatography A
Energetic Materials and Combustion
0.54
article

A fast thermal desorption unit for micro thermal desorption tubes, Part II: Method development and validation for explosives and chemical warfare agent simulants

Peter Boeker, Miriam D. Chopra, Florian Alex Menger, Matthias Wüst, Thomas M. Klapötke, Benny Duong
article en
2 citations

Abstract

A thermal desorption FF-TG-GC/MS method with a cycle time of just 164s including cryofocusing, thermal desorption, analyte separation and system cool down was developed for the analysis of ten explosives and six chemical warfare agent (CWA) simulants. Sampling was carried out both in liquid and gaseous form using micro thermal desorption tubes (μTD-tubes, 1.4mm I.D., 10mg Tenax TA). In addition to the desorption conditions, the effects of deactivated μTD-tubes, the spatial temperature gradient along the separation column and additional cryofocusing to refocus the analytes were evaluated. Limits of detection between 0.17 and 9.18ng/μL and R<sup>2</sup> values ≥0.983 for calibration curves (with the exception of PETN) were obtained. Relative standard deviations of mainly <15% were achieved for within day repeatability. The fluctuations in the peak areas were mostly below 20% with between-day repeatability measured across three days.

Journal of Chromatography AVol. 1739
University of Bonn (DE), Syneos Health (Germany) (DE), Chemisches und Veterinäruntersuchungsamt Ostwestfalen-Lippe (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 38%
Energetic Materials and Combustion
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.