Radiation damage evaluation of YSECT v.2 for spent nuclear fuel inspection in wet storage facility

The Yonsei Single-photon Emission Computed Tomography version 2 (YSECT v.2) for inspection of spent nuclear fuel in the wet storage facility is currently under development. However, the high radiation fields of the facility can potentially damage the system. In this study, we evaluated radiation damage to the scintillator and silicon photomultiplier (SiPM) and its impact on performance. The facility was modeled using Monte Carlo simulation, and the gamma dose and neutron flux delivered to the detector were calculated. Based on the calculated values, experiments were conducted to evaluate damage by irradiating photons and neutrons to the detector. Radiation damage was assessed by comparing 137 Cs spectra obtained before and after irradiation. Additionally, the damage was assessed by comparing the spectra obtained for gamma rays emitted from 252 Cf during neutron irradiation. As a result, no detector damage due to photon irradiation was observed. For neutron irradiation, when the neutron fluence reaches approximately 3.0 × 10 9 neutrons/cm 2 , the signal gain decreases by 16.66 % due to SiPM damage. Nevertheless, there was no change in the measured counts, which are important for image reconstruction of the system. It is expected that the wet storage environment will not affect the results of YSECT v.2 spent fuel inspection.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2024-11-23
DOI
https://doi.org/10.1016/j.net.2024.11.039
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation damage evaluation of YSECT v.2 for spent nuclear fuel inspection in wet storage facility

Chul Hee Min, Yoon Soo Chung, Yong Hyun Chung, Hyung-Joo Choi
1 citations
Nuclear Engineering and Technology
Radiation Detection and Scintillator Technologies
0.61
article

Radiation damage evaluation of YSECT v.2 for spent nuclear fuel inspection in wet storage facility

Chul Hee Min, Yoon Soo Chung, Yong Hyun Chung, Hyung-Joo Choi
article en
1 citations

Abstract

The Yonsei Single-photon Emission Computed Tomography version 2 (YSECT v.2) for inspection of spent nuclear fuel in the wet storage facility is currently under development. However, the high radiation fields of the facility can potentially damage the system. In this study, we evaluated radiation damage to the scintillator and silicon photomultiplier (SiPM) and its impact on performance. The facility was modeled using Monte Carlo simulation, and the gamma dose and neutron flux delivered to the detector were calculated. Based on the calculated values, experiments were conducted to evaluate damage by irradiating photons and neutrons to the detector. Radiation damage was assessed by comparing 137 Cs spectra obtained before and after irradiation. Additionally, the damage was assessed by comparing the spectra obtained for gamma rays emitted from 252 Cf during neutron irradiation. As a result, no detector damage due to photon irradiation was observed. For neutron irradiation, when the neutron fluence reaches approximately 3.0 × 10 9 neutrons/cm 2 , the signal gain decreases by 16.66 % due to SiPM damage. Nevertheless, there was no change in the measured counts, which are important for image reconstruction of the system. It is expected that the wet storage environment will not affect the results of YSECT v.2 spent fuel inspection.

Nuclear Engineering and TechnologyVol. 57(5)
Yonsei University (KR)
Affordable and clean energy
Openalex Percentile: Top 29%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.