Low can be even lower

Low can be even lowerWe read with interest the case report of a successful treatment of an abdominal aortic aneurysm via standard endovascular aortic repair with an ultra-low dose of 2.4 Gycm 2 , published in the August 2024 issue of the Journal. 1 However, we would like to highlight the fact that the radiation dose in this article is not the lowest one reported in the current literature, as the authors state in their article.A few years ago, our group reported an even lower dose area product value of 2.0 Gycm 2 , which was achieved for a standard endovascular aortic aneurysm repair of an infrarenal aortic aneurysm (please refer to Table I [range of dose area product values] of the original article). 2Nevertheless, we would like to commend the authors for observing the as low as reasonably achievable (ALARA) principle and encouraging the readers to do so.Finally, the importance of radiation protection led the European Society for Vascular Surgery to publish the first clinical practice guideline on radiation safety.

Authors

Institutions

Publication Details

Journal
Journal of Vascular Surgery Cases and Innovative Techniques
Published
2024-11-23
DOI
https://doi.org/10.1016/j.jvscit.2024.101693
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low can be even lower

George Panayiotakis, Andreas Tsimpoukis, Fotios O. Efthymiou, Vasileios I Metaxas et al.
Journal of Vascular Surgery Cases and Innovative Techniques
Radiation Dose and Imaging
article

Low can be even lower

George Panayiotakis, Andreas Tsimpoukis, Fotios O. Efthymiou, Vasileios I Metaxas, Stavros K. Kakkos, Christos P. Dimitroukas
article en

Abstract

Low can be even lowerWe read with interest the case report of a successful treatment of an abdominal aortic aneurysm via standard endovascular aortic repair with an ultra-low dose of 2.4 Gycm 2 , published in the August 2024 issue of the Journal. 1 However, we would like to highlight the fact that the radiation dose in this article is not the lowest one reported in the current literature, as the authors state in their article.A few years ago, our group reported an even lower dose area product value of 2.0 Gycm 2 , which was achieved for a standard endovascular aortic aneurysm repair of an infrarenal aortic aneurysm (please refer to Table I [range of dose area product values] of the original article). 2Nevertheless, we would like to commend the authors for observing the as low as reasonably achievable (ALARA) principle and encouraging the readers to do so.Finally, the importance of radiation protection led the European Society for Vascular Surgery to publish the first clinical practice guideline on radiation safety.

Journal of Vascular Surgery Cases and Innovative TechniquesVol. 11(2)
University of Patras (GR)
Openalex Percentile: Top 65%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low can be even lower — George Panayiotakis, Andreas Tsimpoukis, et al. · Journal of Vascular Surgery Cases and Innovative Techniques (2024) | TGRS Research Map | TGRS