Surgical Explantation for Embolized Transcatheter Aortic Valve Replacement Valve at Distal Aortic Arch

The patient was a 65-year-old man with a history of symptomatic aortic stenosis for which he underwent transcatheter aortic valve replacement (TAVR) with a 26-mm balloon-expandable valve through right femoral artery access. The TAVR valve embolized in the distal transverse arch. An additional 29-mm balloon-expandable valve was deployed at the aortic annulus successfully, and the embolized valve remained in the distal arch. The patient subsequently underwent surgical explantation of the embolized valve with central cannulation and deep hypothermic circulatory arrest. The transverse aortic arch was opened, and the embolized valve was removed. His postoperative course was uncomplicated. He was discharged home on postoperative day 6.

Authors

Institutions

Publication Details

Journal
Annals of Thoracic Surgery Short Reports
Published
2024-11-23
DOI
https://doi.org/10.1016/j.atssr.2024.11.006
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical Explantation for Embolized Transcatheter Aortic Valve Replacement Valve at Distal Aortic Arch

Saeed Tarabichi, Eduardo Danduch, Chikashi Nakai, Andrew G. Marthy et al.
Annals of Thoracic Surgery Short Reports
Cardiac Valve Diseases and Treatments
article

Surgical Explantation for Embolized Transcatheter Aortic Valve Replacement Valve at Distal Aortic Arch

Saeed Tarabichi, Eduardo Danduch, Chikashi Nakai, Andrew G. Marthy, Zhang Li, Junyi Liu, Sanjay Samy
article en

Abstract

The patient was a 65-year-old man with a history of symptomatic aortic stenosis for which he underwent transcatheter aortic valve replacement (TAVR) with a 26-mm balloon-expandable valve through right femoral artery access. The TAVR valve embolized in the distal transverse arch. An additional 29-mm balloon-expandable valve was deployed at the aortic annulus successfully, and the embolized valve remained in the distal arch. The patient subsequently underwent surgical explantation of the embolized valve with central cannulation and deep hypothermic circulatory arrest. The transverse aortic arch was opened, and the embolized valve was removed. His postoperative course was uncomplicated. He was discharged home on postoperative day 6.

Annals of Thoracic Surgery Short ReportsVol. 3(2)
Albany Medical Center Hospital (US)
Openalex Percentile: Top 60%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.