Reducing Time Taken to Gather Equipment for Venepuncture and Cannulation: A Quality Improvement Project

Timely gathering of equipment for venepuncture or cannulation on hospital wards is important, particularly in emergency situations. Anecdotally several doctors working at a hospital in England expressed frustration at low equipment stock, layout, and discrepancies between wards leading to significant delays in this process. This quality improvement project therefore aimed to reduce the time taken to gather equipment for venepuncture or cannulation to 20 seconds by June 2023. Methods: Quality improvement methodology was used to define the problem, produce an aim statement, and design several interventions. A flow map was created to understand the equipment collection process, a root cause analysis identified problem areas, and a driver diagram highlighted potential change ideas. A new trolley layout was implemented as part of several plan-do-study-act cycles with the addition of several simple human interventions to maximise its usage. More widespread introduction of identical trolleys across the surgical wards was also achieved. Results: Initial qualitative surveys and the root cause analysis identified a lack of equipment availability, and discrepancies between wards being key barriers to rapid collection of equipment. Prior to any intervention, the average time taken to gather equipment for venepuncture and cannulation was 141 and 137.5 seconds respectively. After implementing a new trolley design and layout, with clear markings and human factor optimisation, the times were reduced to 18 seconds each. Subjective feedback during a cardiac arrest scenario following the intervention was positive. Widespread implementation of the trolleys around the hospital was started following this success although the efficacy of their introduction was not measured during the study period. Conclusion: This quality improvement project successfully reduced the time taken to gather equipment for venepuncture or cannulation on a hospital ward, with positive feedback in an emergency. The project used well-documented quality improvement methodology to achieve this and highlights the ability of empowered clinical staff in non-managerial or non-leadership positions to action change.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-11-23
DOI
https://doi.org/10.7759/cureus.74285
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing Time Taken to Gather Equipment for Venepuncture and Cannulation: A Quality Improvement Project

William C. Butterfield, Ryan Smith, R. M. Myers, Luke Glover et al.
Cureus
Airway Management and Intubation Techniques
article

Reducing Time Taken to Gather Equipment for Venepuncture and Cannulation: A Quality Improvement Project

William C. Butterfield, Ryan Smith, R. M. Myers, Luke Glover, L. Nedic, William Cuthbert
article en

Abstract

Timely gathering of equipment for venepuncture or cannulation on hospital wards is important, particularly in emergency situations. Anecdotally several doctors working at a hospital in England expressed frustration at low equipment stock, layout, and discrepancies between wards leading to significant delays in this process. This quality improvement project therefore aimed to reduce the time taken to gather equipment for venepuncture or cannulation to 20 seconds by June 2023. Methods: Quality improvement methodology was used to define the problem, produce an aim statement, and design several interventions. A flow map was created to understand the equipment collection process, a root cause analysis identified problem areas, and a driver diagram highlighted potential change ideas. A new trolley layout was implemented as part of several plan-do-study-act cycles with the addition of several simple human interventions to maximise its usage. More widespread introduction of identical trolleys across the surgical wards was also achieved. Results: Initial qualitative surveys and the root cause analysis identified a lack of equipment availability, and discrepancies between wards being key barriers to rapid collection of equipment. Prior to any intervention, the average time taken to gather equipment for venepuncture and cannulation was 141 and 137.5 seconds respectively. After implementing a new trolley design and layout, with clear markings and human factor optimisation, the times were reduced to 18 seconds each. Subjective feedback during a cardiac arrest scenario following the intervention was positive. Widespread implementation of the trolleys around the hospital was started following this success although the efficacy of their introduction was not measured during the study period. Conclusion: This quality improvement project successfully reduced the time taken to gather equipment for venepuncture or cannulation on a hospital ward, with positive feedback in an emergency. The project used well-documented quality improvement methodology to achieve this and highlights the ability of empowered clinical staff in non-managerial or non-leadership positions to action change.

CureusVol. 16(11)
Royal Devon & Exeter NHS Foundation Trust (GB)
Industry, innovation and infrastructure
Openalex Percentile: Top 61%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.