Computational modeling of vascular tissue damage for the development of safe interventional devices

During intravascular procedures, medical devices interact mechanically with vascular tissue. The device design faces a trade-off: although a high bending stiffness improves its maneuvrability and deliverability, it may also trigger excessive supra-physiological loading that may result in tissue damage. In particular, the collagen fibers in vascular walls are load-bearing but may rupture on a microscopic scale due to mechanical interaction. When the mechanical load increases even further, tissue rupture or puncture occurs. To mitigate tissue damage, the current work focusses on the development of computational Finite Element (FE) based models wherein state-of-the-art constitutive tissue models are applied toward the design of safe devices. Several experiments are presented for tissue characterization in which device-mimicking indenters are pressed onto a porcine tissue. In these experiments, the Mullins effect, which is related to tissue damage, is observed. Consequently, the mechanical behavior of tissue, including the evolution of damage-induced energy dissipation, is accurately described by adopting a hyperelastic model incorporating the damage approach by Weisbecker et al. (2012). From the experimentally validated computational model, a novel design criterion is established, which allows for safe device development. Furthermore, an energy density criterion for the onset of puncture is proposed. With these tools, several frequently used work-horse guidewires are numerically evaluated.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2024-11-23
DOI
https://doi.org/10.1016/j.jmbbm.2024.106818
Citations
2
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational modeling of vascular tissue damage for the development of safe interventional devices

O. van der Sluis, M.A. Oude Vrielink, P.H.M. Timmermans, B van de Wetering et al.
2 citations
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Elasticity and Material Modeling
0.37
article

Computational modeling of vascular tissue damage for the development of safe interventional devices

O. van der Sluis, M.A. Oude Vrielink, P.H.M. Timmermans, B van de Wetering, R Hovenkamp
article en
2 citations

Abstract

During intravascular procedures, medical devices interact mechanically with vascular tissue. The device design faces a trade-off: although a high bending stiffness improves its maneuvrability and deliverability, it may also trigger excessive supra-physiological loading that may result in tissue damage. In particular, the collagen fibers in vascular walls are load-bearing but may rupture on a microscopic scale due to mechanical interaction. When the mechanical load increases even further, tissue rupture or puncture occurs. To mitigate tissue damage, the current work focusses on the development of computational Finite Element (FE) based models wherein state-of-the-art constitutive tissue models are applied toward the design of safe devices. Several experiments are presented for tissue characterization in which device-mimicking indenters are pressed onto a porcine tissue. In these experiments, the Mullins effect, which is related to tissue damage, is observed. Consequently, the mechanical behavior of tissue, including the evolution of damage-induced energy dissipation, is accurately described by adopting a hyperelastic model incorporating the damage approach by Weisbecker et al. (2012). From the experimentally validated computational model, a novel design criterion is established, which allows for safe device development. Furthermore, an energy density criterion for the onset of puncture is proposed. With these tools, several frequently used work-horse guidewires are numerically evaluated.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 163
NXP (Netherlands) (NL), Philips (Finland) (FI), Philips (Netherlands) (NL), LifeTec Group (Netherlands) (NL)
ITEA, Innovationsfonden, Rijksdienst voor Ondernemend Nederland, Bundesministerium für Bildung und Forschung, Österreichische Forschungsförderungsgesellschaft, ITEA3
Openalex Percentile: Top 42%
Elasticity and Material Modeling
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.