Performance Evaluation of Decentralized Split Unit Air-to-air Heat Pumps

A holistic evaluation is performed to investigate the energy performance of air-to-air split units (also called air-conditioning units), including laboratory measurements and steady-state simulations of the refrigerant cycle. Several aspects are considered, such as indoor fan speed, varying compressor frequency, defrost and “on/off” cycles. The laboratory measurements include steady-state test points as well as dynamic operation.The measured Coefficient of Performance (COP) varies from 1.8 to 4.9, and the maximum measured heating capacity was 2.5 kW, close to the nominal value of 2.7 kW. The measured reduction due to the defrost cycle was up to 14% in the heating capacity and 16% in the COP. It was also found that the indoor air flows were on average 40% less than the ones listed in the datasheet.

Authors

Publication Details

Journal
Proceedings of BauSIM
Published
2024-09-23
DOI
https://doi.org/10.26868/29761662.2024.47
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of Decentralized Split Unit Air-to-air Heat Pumps

William Monteleone, Fabian Ochs, Georgios Dermentzis, Anastasios Tsaris
Proceedings of BauSIM
Refrigeration and Air Conditioning Technologies
article

Performance Evaluation of Decentralized Split Unit Air-to-air Heat Pumps

William Monteleone, Fabian Ochs, Georgios Dermentzis, Anastasios Tsaris
article en

Abstract

A holistic evaluation is performed to investigate the energy performance of air-to-air split units (also called air-conditioning units), including laboratory measurements and steady-state simulations of the refrigerant cycle. Several aspects are considered, such as indoor fan speed, varying compressor frequency, defrost and “on/off” cycles. The laboratory measurements include steady-state test points as well as dynamic operation.The measured Coefficient of Performance (COP) varies from 1.8 to 4.9, and the maximum measured heating capacity was 2.5 kW, close to the nominal value of 2.7 kW. The measured reduction due to the defrost cycle was up to 14% in the heating capacity and 16% in the COP. It was also found that the indoor air flows were on average 40% less than the ones listed in the datasheet.

Proceedings of BauSIMVol. 10
Affordable and clean energy
Openalex Percentile: Top 79%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.