Geophysical Determination of Aquifer Parameters in Basement Complex Rocks through Vertical Electrical Sounding Data Analysis from part of Ilorin East Southwestern Nigeria

This research employed vertical electrical sounding data collected from the Ilorin East region of Southwest Nigeria to analyse aquifer properties within Basement Complex rocks. Its objective was to assess the aquifer's attributes in the area through statistical methods and electrical resistivity. Geoelectrical profiling revealed four distinct layers beneath the surface: lateritic layer, topsoil, weathered rock, and fresh basement. The third and fourth layers were identified at depths between 8.47 and 33.2 meters, with aquifer resistivity values ranging from 76.6 to 1576 Ωm. The fractured rocks in the region possess a moderate permeability due to moderate weathering. The aquifer's characteristics were evaluated based on four parameters: transmissivity, apparent resistivity, depth to bedrock, and aquifer thickness. The findings ranging from 0.74- 33.2 m indicate varying groundwater potential across the study area, ranging from low to high.

Publication Details

Journal
Ilorin Journal of Science
Published
2024-11-03
DOI
https://doi.org/10.54908/iljs.fapscon.2024.11.03.1026
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geophysical Determination of Aquifer Parameters in Basement Complex Rocks through Vertical Electrical Sounding Data Analysis from part of Ilorin East Southwestern Nigeria

Ilorin Journal of Science
Geophysical and Geoelectrical Methods
article

Geophysical Determination of Aquifer Parameters in Basement Complex Rocks through Vertical Electrical Sounding Data Analysis from part of Ilorin East Southwestern Nigeria

article en

Abstract

This research employed vertical electrical sounding data collected from the Ilorin East region of Southwest Nigeria to analyse aquifer properties within Basement Complex rocks. Its objective was to assess the aquifer's attributes in the area through statistical methods and electrical resistivity. Geoelectrical profiling revealed four distinct layers beneath the surface: lateritic layer, topsoil, weathered rock, and fresh basement. The third and fourth layers were identified at depths between 8.47 and 33.2 meters, with aquifer resistivity values ranging from 76.6 to 1576 Ωm. The fractured rocks in the region possess a moderate permeability due to moderate weathering. The aquifer's characteristics were evaluated based on four parameters: transmissivity, apparent resistivity, depth to bedrock, and aquifer thickness. The findings ranging from 0.74- 33.2 m indicate varying groundwater potential across the study area, ranging from low to high.

Ilorin Journal of Science
Openalex Percentile: Top 79%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies