Accelerated protein retention expansion microscopy using microwave radiation

Protein retention expansion microscopy (ExM) retains fluorescent signals in fixed tissue and isotropically expands the tissue to allow nanoscale (<70 nm) resolution on diffraction-limited confocal microscopes. Despite the numerous advantages of ExM, the protocol is time-consuming. Here, we adapted an ExM protocol to vibratome-sectioned brain tissue of Xenopus laevis tadpoles and implemented a microwave (M/W)-assisted protocol (<sup>M/W</sup>ExM) to reduce the workflow from days to hours. Our <sup>M/W</sup>ExM protocol maintains the superior resolution of the original ExM protocol and yields a higher magnitude of expansion, suggesting that M/W radiation may also facilitate the expansion process. We then adapted the M/W protocol to the whole-mount brain of Drosophila melanogaster fruit flies, and successfully reduced the processing time of a widely used Drosophila IHC-ExM protocol from 6 to 2 days. This demonstrates that with appropriate adjustment of M/W parameters, this protocol can be readily adapted to different organisms and tissue types to greatly increase the efficiency of ExM experiments.

Authors

Institutions

Publication Details

Journal
Cell Reports Methods
Published
2024-11-22
DOI
https://doi.org/10.1016/j.crmeth.2024.100907
Citations
1
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerated protein retention expansion microscopy using microwave radiation

Hai‐yan He, Juan Martinez-Cervantes, Meghan R Bullard, Norisha B Quaicoe et al.
1 citations
Cell Reports Methods
Monoclonal and Polyclonal Antibodies Research
0.40
article

Accelerated protein retention expansion microscopy using microwave radiation

Hai‐yan He, Juan Martinez-Cervantes, Meghan R Bullard, Norisha B Quaicoe, Elena Iliadis, Isaac Cervantes-Sandoval, Tess M Seidler, Amanda Jin, Dennis A. Adams, Jessica M Lin
article en
1 citations

Abstract

Protein retention expansion microscopy (ExM) retains fluorescent signals in fixed tissue and isotropically expands the tissue to allow nanoscale (<70 nm) resolution on diffraction-limited confocal microscopes. Despite the numerous advantages of ExM, the protocol is time-consuming. Here, we adapted an ExM protocol to vibratome-sectioned brain tissue of Xenopus laevis tadpoles and implemented a microwave (M/W)-assisted protocol (<sup>M/W</sup>ExM) to reduce the workflow from days to hours. Our <sup>M/W</sup>ExM protocol maintains the superior resolution of the original ExM protocol and yields a higher magnitude of expansion, suggesting that M/W radiation may also facilitate the expansion process. We then adapted the M/W protocol to the whole-mount brain of Drosophila melanogaster fruit flies, and successfully reduced the processing time of a widely used Drosophila IHC-ExM protocol from 6 to 2 days. This demonstrates that with appropriate adjustment of M/W parameters, this protocol can be readily adapted to different organisms and tissue types to greatly increase the efficiency of ExM experiments.

Cell Reports MethodsVol. 4(12)
Georgetown University (US)
Georgetown University, National Institutes of Health, National Institute of Neurological Disorders and Stroke, National Center for Advancing Translational Sciences
Affordable and clean energy
Openalex Percentile: Top 32%
Monoclonal and Polyclonal Antibodies Research
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.