Research on Fault Self-Healing Method of Distribution Network Based on SOP and Distributed Protection

Under the background of ‘double carbon’, large-scale distributed power supply is added, and the operation mode is becoming more and more complex, which greatly increases the difficulty of self-healing control. Because SOP has the ability to implement power flow control, according to the distributed power supply and SOP access distribution network as the research background, the distributed protection of a new distribution network with SOP is studied, and the fault isolation and self-healing scheme based on multi-terminal information is given. Combined with the 10kV distribution network, the application analysis of the self-healing scheme is carried out. The results show that the scheme can effectively realize the fault self-healing of the distribution network.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10754414
Citations
1
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Fault Self-Healing Method of Distribution Network Based on SOP and Distributed Protection

Ling He, Xiaorong Li, Tian Tian, Beibei Zhang et al.
1 citations
Smart Grid and Power Systems
0.21
article

Research on Fault Self-Healing Method of Distribution Network Based on SOP and Distributed Protection

Ling He, Xiaorong Li, Tian Tian, Beibei Zhang, Wang Mengke, He Weixiang
article en
1 citations

Abstract

Under the background of ‘double carbon’, large-scale distributed power supply is added, and the operation mode is becoming more and more complex, which greatly increases the difficulty of self-healing control. Because SOP has the ability to implement power flow control, according to the distributed power supply and SOP access distribution network as the research background, the distributed protection of a new distribution network with SOP is studied, and the fault isolation and self-healing scheme based on multi-terminal information is given. Combined with the 10kV distribution network, the application analysis of the self-healing scheme is carried out. The results show that the scheme can effectively realize the fault self-healing of the distribution network.

Shanghai Electric (China) (CN)
Openalex Percentile: Top 46%
Smart Grid and Power Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.