Anti-Islanding Protection Method for Ratio Measurement by Voltage Signal Synchronization

Anti-islanding protection based on impedance measurement can effectively avoid the problems of refusal and maloperation. But existing methods fail to establish a unified identification criterion in different islanding systems, and the mutual interference of the detection signals in the multi-DG system will lead to the protection failure. In this regard, a new islanding identification method is constructed by utilizing the ratio of the islanding detection signal to the grid voltage, which frees the criterion setting from the dependence on the system impedance parameter. In addition, the self-synchronization strategy proposed in this method allows each DG to synchronize the injected signals spontaneously by using the islanding detection signal and the voltage crossing point. Finally, simulation experiments based on a real-time digital simulation system (RTDS) verify the feasibility and effectiveness of the present methods.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10754509
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti-Islanding Protection Method for Ratio Measurement by Voltage Signal Synchronization

Xinhui Zhang, Yu Chen, Huabo Xu, Jiaqi Li et al.
Islanding Detection in Power Systems
article

Anti-Islanding Protection Method for Ratio Measurement by Voltage Signal Synchronization

Xinhui Zhang, Yu Chen, Huabo Xu, Jiaqi Li, Yiming Liu, Bingyin Xu
article en

Abstract

Anti-islanding protection based on impedance measurement can effectively avoid the problems of refusal and maloperation. But existing methods fail to establish a unified identification criterion in different islanding systems, and the mutual interference of the detection signals in the multi-DG system will lead to the protection failure. In this regard, a new islanding identification method is constructed by utilizing the ratio of the islanding detection signal to the grid voltage, which frees the criterion setting from the dependence on the system impedance parameter. In addition, the self-synchronization strategy proposed in this method allows each DG to synchronize the injected signals spontaneously by using the islanding detection signal and the voltage crossing point. Finally, simulation experiments based on a real-time digital simulation system (RTDS) verify the feasibility and effectiveness of the present methods.

Shandong University of Technology (CN), Zibo Vocational Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.