Evaluation of Technical Consequences of Line Arresters instead of Shield Wires on HV Overhead Transmission Lines

Ensuring the reliability of overhead transmission lines and reducing outages is of utmost importance in the power industry. Lightning strikes and back flash-over incidents are significant contributors to disruptions in service. While shield wires have traditionally been used to mitigate the impact of lightning, they have limitations, particularly in high-risk areas or specific tower configurations. Some experts advocate for the use of line surge arresters as a more effective solution. this study delves into the application of line surge arresters to enhance the reliability and performance of overhead transmission lines in the face of lightning strikes and other electrical disturbances. Line surge arresters are engineered to redirect excess voltage away from the transmission lines, thereby decreasing the likelihood of damage from lightning strikes. by incorporating these devices, utilities can bolster the resilience of their infrastructure and reduce downtime resulting from electrical disturbances. this proactive approach not only leads to cost savings but also elevates customer satisfaction. the utilization of EMTP and DIgSILENT software has been instrumental in conducting simulations for this study.

Authors

Institutions

Publication Details

Published
2024-10-17
DOI
https://doi.org/10.1109/epei63510.2024.10758178
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Technical Consequences of Line Arresters instead of Shield Wires on HV Overhead Transmission Lines

Mohammad Loni, Hamed Farahani, Faramarz Ghelichi, Hamid Javadi et al.
Power Line Inspection Robots
article

Evaluation of Technical Consequences of Line Arresters instead of Shield Wires on HV Overhead Transmission Lines

Mohammad Loni, Hamed Farahani, Faramarz Ghelichi, Hamid Javadi, Masoud Negarpour
article en

Abstract

Ensuring the reliability of overhead transmission lines and reducing outages is of utmost importance in the power industry. Lightning strikes and back flash-over incidents are significant contributors to disruptions in service. While shield wires have traditionally been used to mitigate the impact of lightning, they have limitations, particularly in high-risk areas or specific tower configurations. Some experts advocate for the use of line surge arresters as a more effective solution. this study delves into the application of line surge arresters to enhance the reliability and performance of overhead transmission lines in the face of lightning strikes and other electrical disturbances. Line surge arresters are engineered to redirect excess voltage away from the transmission lines, thereby decreasing the likelihood of damage from lightning strikes. by incorporating these devices, utilities can bolster the resilience of their infrastructure and reduce downtime resulting from electrical disturbances. this proactive approach not only leads to cost savings but also elevates customer satisfaction. the utilization of EMTP and DIgSILENT software has been instrumental in conducting simulations for this study.

Iran Khodro (Iran) (IR)
Openalex Percentile: Top 79%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Technical Consequences of Line Arresters instead of Shield Wires on HV Overhead Transmission Lines — Mohammad Loni, Hamed Farahani, et al. · (2024) | TGRS Research Map | TGRS