A Permanent Fault Identification Method for Distribution Networks Based on Sequential Reclosing

Aiming at the problem that blind reclosing to permanent faults will bring secondary impacts to the distribution network, a permanent fault identification method for distribution network based on sequential reclosing is proposed. Firstly, the analysis model of using a phase segregated switch in distribution network is established. The expressions of active power of reclosing phase under temporary and permanent faults with different neutral grounding modes are derived, and the difference of active power for different fault properties is obtained. Secondly, the criterion of permanent fault identification based on active power is constructed. The influence of transition resistance, load capacity and other factors is analyzed. Finally, the reclosing strategy is proposed. PSCAD/EMTDC simulation results verify that the theoretical analysis is correct, and the proposed permanent fault identification method is highly sensitive.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10754069
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Permanent Fault Identification Method for Distribution Networks Based on Sequential Reclosing

Zhongxue Chang, Guobing Song, Wei Zhang, Huan Li
Smart Grid Security and Resilience
article

A Permanent Fault Identification Method for Distribution Networks Based on Sequential Reclosing

Zhongxue Chang, Guobing Song, Wei Zhang, Huan Li
article en

Abstract

Aiming at the problem that blind reclosing to permanent faults will bring secondary impacts to the distribution network, a permanent fault identification method for distribution network based on sequential reclosing is proposed. Firstly, the analysis model of using a phase segregated switch in distribution network is established. The expressions of active power of reclosing phase under temporary and permanent faults with different neutral grounding modes are derived, and the difference of active power for different fault properties is obtained. Secondly, the criterion of permanent fault identification based on active power is constructed. The influence of transition resistance, load capacity and other factors is analyzed. Finally, the reclosing strategy is proposed. PSCAD/EMTDC simulation results verify that the theoretical analysis is correct, and the proposed permanent fault identification method is highly sensitive.

Xi'an Jiaotong University (CN)
State Grid Corporation of China
Climate action
Openalex Percentile: Top 75%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.