Analysis and Circuit Design of Imbalanced Impedance Channels for Conductive Intracardiac Communication

Conductive Intracardiac Communication (CIC) uses cardiac tissue as a transmission medium for short-range wireless communication and is a potential method for enabling leadless multi-chamber pacing. However, the characterization of the intracardiac channel is significantly influenced by the experimental setup and conditions. The reported results in the literature vary depending on the measurement methods used, posing challenges in obtaining reliable channel characterization for CIC. In this paper, we aim to investigate the effects of different measurement devices and conditions on the intracardiac channel. By clarifying how impedance imbalance affects the gain measurement results, we design a weak-signal measurement circuit with high common-mode rejection. This new circuit provides a more accurate and effective gain measurement scheme for the CIC channel. An equivalent circuit model simulating cardiac biomechanical impedance is constructed to analyze how capacitive and resistive imbalances affect the gain measurement results. The effects of these imbalances are verified by intracardiac channel impedance imbalance experiments. A high common-mode rejection-high-resistance differential measurement circuit that can reduce the effects of capacitive and resistive imbalances simultaneously, is then designed to suppress the interference in the experiments. The results show that changes in the measurement equipment and isolation method lead to variations in the coupling circuit characteristics, causing differences of up to 16.65 dB in the measurement results. Experiments using the designed measurement circuits effectively mitigate interference from impedance imbalance on the measurement results. This study identifies the reasons behind the discrepancies in the experimental results of previous studies and provides a more reliable gain measurement scheme for CIC research.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2024-11-22
DOI
https://doi.org/10.1109/tbcas.2024.3504832
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Circuit Design of Imbalanced Impedance Channels for Conductive Intracardiac Communication

Hung Chun Li, Yueming Gao, Mang I Vai, Sio Hang Pun et al.
IEEE Transactions on Biomedical Circuits and Systems
ECG Monitoring and Analysis
article

Analysis and Circuit Design of Imbalanced Impedance Channels for Conductive Intracardiac Communication

Hung Chun Li, Yueming Gao, Mang I Vai, Sio Hang Pun, Dongming Li, Jiejie Yang, Han Wang
article en

Abstract

Conductive Intracardiac Communication (CIC) uses cardiac tissue as a transmission medium for short-range wireless communication and is a potential method for enabling leadless multi-chamber pacing. However, the characterization of the intracardiac channel is significantly influenced by the experimental setup and conditions. The reported results in the literature vary depending on the measurement methods used, posing challenges in obtaining reliable channel characterization for CIC. In this paper, we aim to investigate the effects of different measurement devices and conditions on the intracardiac channel. By clarifying how impedance imbalance affects the gain measurement results, we design a weak-signal measurement circuit with high common-mode rejection. This new circuit provides a more accurate and effective gain measurement scheme for the CIC channel. An equivalent circuit model simulating cardiac biomechanical impedance is constructed to analyze how capacitive and resistive imbalances affect the gain measurement results. The effects of these imbalances are verified by intracardiac channel impedance imbalance experiments. A high common-mode rejection-high-resistance differential measurement circuit that can reduce the effects of capacitive and resistive imbalances simultaneously, is then designed to suppress the interference in the experiments. The results show that changes in the measurement equipment and isolation method lead to variations in the coupling circuit characteristics, causing differences of up to 16.65 dB in the measurement results. Experiments using the designed measurement circuits effectively mitigate interference from impedance imbalance on the measurement results. This study identifies the reasons behind the discrepancies in the experimental results of previous studies and provides a more reliable gain measurement scheme for CIC research.

IEEE Transactions on Biomedical Circuits and SystemsVol. 19(4)
Analog Devices (United States) (US), University of Macau (MO), Zhuhai Institute of Advanced Technology (CN), Fuzhou University (CN)
Openalex Percentile: Top 60%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.