Spatiotemporal Imaging of Extra-/Intracellular Ion Concentrations by Multifrequency Complex Electrical Impedance Tomography (<i>mfc</i>-EIT)
The multifrequency complex electrical impedance tomography (mfc-EIT) has been proposed to image the spatiotemporal extra-/intracellular ion concentrations. In mfc-EIT, four frequency-dependent Jacobian matrices described by the partial derivatives of complex impedance (resistance and reactance) with respect to complex conductivity (conductivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and relative permittivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula>) as a function of radial frequency <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\omega $ </tex-math></inline-formula> are newly introduced as a complex Jacobian matrix. The mfc-EIT inversely reconstructs the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula> images as a function of frequency from the complex impedance. Based on the electric field simulation, the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula> images reconstructed by mfc-EIT and conventional EIT with a general Jacobian matrix are evaluated by spectral stabilities <SS> which is an indicator of reasonable spectral trend. The <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula> images by mfc-EIT have lower <SS> (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula>: <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.7\times 10^{-9}$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula>: <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.0\times 10^{-4}$ </tex-math></inline-formula>) than those by conventional EIT (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula>: <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.5\times 10^{-8}$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula>: <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.6\times 10^{-3}$ </tex-math></inline-formula>), which indicates that mfc-EIT reconstructs the reasonable frequency response. The mfc-EIT is also applied to the imaging of the extra/intrace-cellular ion transfer around cell-spheroids in experiment. According to the reconstructed <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula> images, the extracellular ion concentration reflected by <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$f=1$ </tex-math></inline-formula> kHz are increased over time, while the intracellular ion concentration reflected by <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\sigma $ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varepsilon $ </tex-math></inline-formula> at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$f=1$ </tex-math></inline-formula> MHz are decreased over time, which is attributed to the ion transfer via the ion channel. Thus, mfc-EIT captures the extra-/intracellular ion concentration changes by ion transfer via ion channels.
Authors
- Daisuke Kawashima (ORCID: https://orcid.org/0000-0002-1523-6206)
- Songshi Li (ORCID: https://orcid.org/0000-0001-6687-119X)
- Hiromichi OBARA (ORCID: https://orcid.org/0000-0003-0662-6138)
- Masahiro Takei
Institutions
- Chiba University (JP)
- Tokyo Metropolitan University (JP)
Publication Details
- Journal
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2024-11-22
- DOI
- https://doi.org/10.1109/tim.2024.3502740
- Citations
- 3
- Primary Topic
- Electrical and Bioimpedance Tomography
- Type
- article
- Field-Weighted Citation Impact
- 0.63