Method for Identifying Tree-Contact Fault Timing Based on Dynamic Zero-Sequence Current Amplification Fitting

To address the challenge of estimating the occurrence time of Tree contact Single-phase-to-ground Fault in overhead conductors, a 10 kV conductor-to-tree real-scale test platform was established. By observing the experimental phenomena, the fault development mechanism was elucidated, and the common characteristics of fault zero-sequence current rise based on the thermal effect mechanism were summarized. A method for estimating the fault initiation time of conductor-to-tree contact based on the long-time window linear coupling of the effective value of zero-sequence current was proposed. Simulation and experimental results indicate that, compared to the traditional threshold method, this approach reduces the estimation error of the fault initiation time by up to 84.51 %.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10754496
Primary Topic
Software System Performance and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for Identifying Tree-Contact Fault Timing Based on Dynamic Zero-Sequence Current Amplification Fitting

Liang Dong, Jiaming Liu, Pengwei Wang, Bingyin Xu et al.
Software System Performance and Reliability
article

Method for Identifying Tree-Contact Fault Timing Based on Dynamic Zero-Sequence Current Amplification Fitting

Liang Dong, Jiaming Liu, Pengwei Wang, Bingyin Xu, Zhao Weitong
article en

Abstract

To address the challenge of estimating the occurrence time of Tree contact Single-phase-to-ground Fault in overhead conductors, a 10 kV conductor-to-tree real-scale test platform was established. By observing the experimental phenomena, the fault development mechanism was elucidated, and the common characteristics of fault zero-sequence current rise based on the thermal effect mechanism were summarized. A method for estimating the fault initiation time of conductor-to-tree contact based on the long-time window linear coupling of the effective value of zero-sequence current was proposed. Simulation and experimental results indicate that, compared to the traditional threshold method, this approach reduces the estimation error of the fault initiation time by up to 84.51 %.

Shandong University of Technology (CN)
Climate action
Openalex Percentile: Top 76%
Software System Performance and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.