Improved Single Current Loop Control of Grid-Connected PV for Harmonic Reduction in Distribution Network

This paper proposes an improved single current loop multiple quasi-proportional resonant (QPR) control strategy based on the traditional proportional resonant (PR) control strategy to address issues of system instability and high harmonic content in grid-connected current caused by the LCL filter at specific frequencies. The sliding mode controller (SMC) is employed in the voltage outer loop, while active damping single current loop feedback is used in the current loop to suppress the resonant peak. Additionally, the multiple QPR controller minimizes harmonic content and enhances power quality. The MATLAB/Simulink program is utilized to study the grid-connected three-phase photovoltaic (PV) system's anti-interference capabilities and the harmonic content of the grid-connected current. The results demonstrate that the proposed method enhances the system's anti-interference capability and significantly reduces the harmonic content of the grid-connected current.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10753687
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Single Current Loop Control of Grid-Connected PV for Harmonic Reduction in Distribution Network

Ying Xue, Xiaowen Zhu, Shaohua Wang, Zhiyi Zhao et al.
Power Systems and Renewable Energy
article

Improved Single Current Loop Control of Grid-Connected PV for Harmonic Reduction in Distribution Network

Ying Xue, Xiaowen Zhu, Shaohua Wang, Zhiyi Zhao, Shiyun Chen, Kai Zhang
article en

Abstract

This paper proposes an improved single current loop multiple quasi-proportional resonant (QPR) control strategy based on the traditional proportional resonant (PR) control strategy to address issues of system instability and high harmonic content in grid-connected current caused by the LCL filter at specific frequencies. The sliding mode controller (SMC) is employed in the voltage outer loop, while active damping single current loop feedback is used in the current loop to suppress the resonant peak. Additionally, the multiple QPR controller minimizes harmonic content and enhances power quality. The MATLAB/Simulink program is utilized to study the grid-connected three-phase photovoltaic (PV) system's anti-interference capabilities and the harmonic content of the grid-connected current. The results demonstrate that the proposed method enhances the system's anti-interference capability and significantly reduces the harmonic content of the grid-connected current.

China Southern Power Grid (China) (CN), South China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improved Single Current Loop Control of Grid-Connected PV for Harmonic Reduction in Distribution Network — Ying Xue, Xiaowen Zhu, et al. · (2024) | TGRS Research Map | TGRS