Earth Fault Detection Method for TN-C-S Systems Based on Residual Current Shunt Coefficients

TN-C-S systems are widely used in low-voltage distribution networks (LVDNs). However, the PEN conductor of the TN-C-S system is earthed at multiple points, causing changes in residual currents during load switching. Existing earth fault detection methods cannot distinguish this residual current change caused by load switching, which will lead to mal-operation. To address this problem, the residual currents during a steady state, load switching, and an earth fault are derived. It is found that the residual current shunt coefficient during load switching is the same as that in the steady state, but is different from that during the earth fault. Record the residual current shunt coefficient when devices are powered on. Then, calculate the residual current deviation shunt coefficient when the residual current changes. Earth faults can be discriminated by comparing the difference between the calculated shunt coefficients and the recorded shunt coefficients. The reliability of the proposed method was verified by both digital simulations and physical tests in an actual LVDN.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10753918
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Earth Fault Detection Method for TN-C-S Systems Based on Residual Current Shunt Coefficients

Zhongyu Sun, Licheng Zhang, Shanzhong Fang, Binyin Xu et al.
Fault Detection and Control Systems
article

Earth Fault Detection Method for TN-C-S Systems Based on Residual Current Shunt Coefficients

Zhongyu Sun, Licheng Zhang, Shanzhong Fang, Binyin Xu, Wei Wang
article en

Abstract

TN-C-S systems are widely used in low-voltage distribution networks (LVDNs). However, the PEN conductor of the TN-C-S system is earthed at multiple points, causing changes in residual currents during load switching. Existing earth fault detection methods cannot distinguish this residual current change caused by load switching, which will lead to mal-operation. To address this problem, the residual currents during a steady state, load switching, and an earth fault are derived. It is found that the residual current shunt coefficient during load switching is the same as that in the steady state, but is different from that during the earth fault. Record the residual current shunt coefficient when devices are powered on. Then, calculate the residual current deviation shunt coefficient when the residual current changes. Earth faults can be discriminated by comparing the difference between the calculated shunt coefficients and the recorded shunt coefficients. The reliability of the proposed method was verified by both digital simulations and physical tests in an actual LVDN.

Shandong University of Technology (CN), Shandong University (CN)
Climate action
Openalex Percentile: Top 75%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Earth Fault Detection Method for TN-C-S Systems Based on Residual Current Shunt Coefficients — Zhongyu Sun, Licheng Zhang, et al. · (2024) | TGRS Research Map | TGRS