Numerical Calculation of Real-Time Ampacity of High Voltage Power Cable Duct Laying Based on Environmental Information

In order to fully utilize the current-carrying capacity of power cables, it is demanding to accurately calculate cables real-time ampacity. In this point of view, a real-time ampacity calculation methodology based on environmental information is proposed. Firstly, a coupled multi-physics cable model is constructed. Secondly, the real-time environmental information is obtained based on a thermocouple and a distributed optical fiber temperature measurement system (DTS). Based on these, the real-time ampacity of cables is calculated by Newton method. The numerical results on a case study indicate that the real-time ampacity calculated by using the proposed methodology is approximately 39.08% higher as compared to the nominal ampacity.

Authors

Institutions

Publication Details

Published
2024-09-12
DOI
https://doi.org/10.1109/ciced63421.2024.10754276
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Calculation of Real-Time Ampacity of High Voltage Power Cable Duct Laying Based on Environmental Information

Wen Dai, Wei Li, Guolin Wan, Jun Liu et al.
Thermal Analysis in Power Transmission
article

Numerical Calculation of Real-Time Ampacity of High Voltage Power Cable Duct Laying Based on Environmental Information

Wen Dai, Wei Li, Guolin Wan, Jun Liu, Linfeng Chen, Xiaoyu Zhou, Yuhan Jiang, Shiyou Yang, Yuntu Jiang, Yuan Liu
article en

Abstract

In order to fully utilize the current-carrying capacity of power cables, it is demanding to accurately calculate cables real-time ampacity. In this point of view, a real-time ampacity calculation methodology based on environmental information is proposed. Firstly, a coupled multi-physics cable model is constructed. Secondly, the real-time environmental information is obtained based on a thermocouple and a distributed optical fiber temperature measurement system (DTS). Based on these, the real-time ampacity of cables is calculated by Newton method. The numerical results on a case study indicate that the real-time ampacity calculated by using the proposed methodology is approximately 39.08% higher as compared to the nominal ampacity.

Shanghai Electric (China) (CN), Zhejiang University (CN)
Life in Land
Openalex Percentile: Top 75%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical Calculation of Real-Time Ampacity of High Voltage Power Cable Duct Laying Based on Environmental Information — Wen Dai, Wei Li, et al. · (2024) | TGRS Research Map | TGRS