Toward Highly Flexible Inter-User Calibration of Myoelectric Control Models With User-Defined Hand Gestures

Myoelectric control models enabling accurate hand gesture recognition via electromyography (EMG) have attracted increasing attentions in rehabilitation robotics. Adapting pre-trained models to new users is a main challenge in real world applications due to the inter-user different EMG characteristics. Most previous transfer learning approaches employed a rigid model calibration process, usually in a supervised manner with ground truth labels, or in an unsupervised manner but still requiring users to perform pre-defined hand gestures to update model parameters. We argue that such a rigid model calibration process lacks flexibility and limit the translation of myoelectric control into real world practice. In this work, we gradually “flexibilize” the standard model calibration process toward a highly flexible version, which does not require the labels of calibration data, and can be performed on only a subset of pre-defined hand gestures or even unknown user-defined hand gestures. We identify those key components contributing to the performance difference along the way. Compared with the supervised method, the unsupervised model calibration even contributed to a 10% improvement (<inline-formula> <tex-math notation="LaTeX">${p}\lt 0.05$ </tex-math></inline-formula>) in case where only a subset of gesture categories were available for model calibration. Moreover, the unsupervised model calibration achieved a highest recognition accuracy of 86.57% using unknown user-defined gestures, with no significant difference compared to the accuracy with pre-defined gestures (<inline-formula> <tex-math notation="LaTeX">${p}\gt 0.05$ </tex-math></inline-formula>).

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2024-11-22
DOI
https://doi.org/10.1109/tmrb.2024.3504737
Citations
3
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Highly Flexible Inter-User Calibration of Myoelectric Control Models With User-Defined Hand Gestures

Xinyu Jiang, Yangyang Yuan, Chih-Hong Chou, Jionghui Liu et al.
3 citations
IEEE Transactions on Medical Robotics and Bionics
Muscle activation and electromyography studies
0.55
article

Toward Highly Flexible Inter-User Calibration of Myoelectric Control Models With User-Defined Hand Gestures

Xinyu Jiang, Yangyang Yuan, Chih-Hong Chou, Jionghui Liu, Chenyun Dai, Zihao Chen
article en
3 citations

Abstract

Myoelectric control models enabling accurate hand gesture recognition via electromyography (EMG) have attracted increasing attentions in rehabilitation robotics. Adapting pre-trained models to new users is a main challenge in real world applications due to the inter-user different EMG characteristics. Most previous transfer learning approaches employed a rigid model calibration process, usually in a supervised manner with ground truth labels, or in an unsupervised manner but still requiring users to perform pre-defined hand gestures to update model parameters. We argue that such a rigid model calibration process lacks flexibility and limit the translation of myoelectric control into real world practice. In this work, we gradually “flexibilize” the standard model calibration process toward a highly flexible version, which does not require the labels of calibration data, and can be performed on only a subset of pre-defined hand gestures or even unknown user-defined hand gestures. We identify those key components contributing to the performance difference along the way. Compared with the supervised method, the unsupervised model calibration even contributed to a 10% improvement (<inline-formula> <tex-math notation="LaTeX">${p}\lt 0.05$ </tex-math></inline-formula>) in case where only a subset of gesture categories were available for model calibration. Moreover, the unsupervised model calibration achieved a highest recognition accuracy of 86.57% using unknown user-defined gestures, with no significant difference compared to the accuracy with pre-defined gestures (<inline-formula> <tex-math notation="LaTeX">${p}\gt 0.05$ </tex-math></inline-formula>).

IEEE Transactions on Medical Robotics and BionicsVol. 7(1)
Georgia Institute of Technology (US), Shanghai Jiao Tong University (CN), Fudan University (CN), Shanghai Institute for Science of Science (CN), Shanghai Center for Brain Science and Brain-Inspired Technology (CN), University of Edinburgh (GB)
National Natural Science Foundation of China
Openalex Percentile: Top 36%
Muscle activation and electromyography studies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.