Industrial operators aim to adopt proactive asset management strategies. However, changes in workplace tenure have led to reduced operator expertise, hindering this goal. Shifting from manually detecting equipment problems, to using automated technology with predictive analysis can help address this challenge. However, legacy systems, like the Supervisory Control and Data Acquisition (SCADA), are not well-suited to scalable predictive approaches. SCADA is widely used to manually monitor and manage distributed physical assets. Supporting infrastructure was designed and optimized for that need. Specialized communication protocols are utilized for applications which span large geographical deployments. These protocols ensure data robustness and consistency in variable-quality network environments. However, the resulting data, while forming enterprise data pipelines, lacks granularity and has irregular time spacing, making it unsuitable for machine learning applications. We present a hybrid cloud-to-edge health monitoring solution for assets connected to SCADA or other legacy control systems. Our solution uses a modbus-based polling system on the edge, to collect data at a much higher granularity than the adjacent SCADA system, letting us detect even subtle and acute patterns in the data. Note that no new sensors are needed, as we connect to the same registers as the existing SCADA system. The high granularity data is assessed at the edge for anomalies, using time series anomaly detection algorithms. We then synthesize the prediction into a health index that quantifies the recency and the frequency of the detected anomalies for the asset. The health index is then transmitted to a web-based application, where the user can configure thresholds for generating alerts based on the criticality of the asset. We demonstrate our solution in a case study, where the application was deployed using Schneider Electric's Customer First Digital Hub, to monitor a sewage pump station for blockages and other subtle deviations in operating patterns.

Authors

Institutions

Publication Details

Journal
Annual Conference of the PHM Society
Published
2024-11-05
DOI
https://doi.org/10.36001/phmconf.2024.v16i1.3870
Citations
2
Primary Topic
Anomaly Detection Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Health Assessment of Pump Stations using Time Series Anomaly Detection

Willem Malloy, Babak Afshin‐Pour, Abhishek Murthy, Vasileios Geroulas
2 citations
Annual Conference of the PHM Society
Anomaly Detection Techniques and Applications
0.30
article

Health Assessment of Pump Stations using Time Series Anomaly Detection

Willem Malloy, Babak Afshin‐Pour, Abhishek Murthy, Vasileios Geroulas
article en
2 citations

Abstract

Industrial operators aim to adopt proactive asset management strategies. However, changes in workplace tenure have led to reduced operator expertise, hindering this goal. Shifting from manually detecting equipment problems, to using automated technology with predictive analysis can help address this challenge. However, legacy systems, like the Supervisory Control and Data Acquisition (SCADA), are not well-suited to scalable predictive approaches. SCADA is widely used to manually monitor and manage distributed physical assets. Supporting infrastructure was designed and optimized for that need. Specialized communication protocols are utilized for applications which span large geographical deployments. These protocols ensure data robustness and consistency in variable-quality network environments. However, the resulting data, while forming enterprise data pipelines, lacks granularity and has irregular time spacing, making it unsuitable for machine learning applications. We present a hybrid cloud-to-edge health monitoring solution for assets connected to SCADA or other legacy control systems. Our solution uses a modbus-based polling system on the edge, to collect data at a much higher granularity than the adjacent SCADA system, letting us detect even subtle and acute patterns in the data. Note that no new sensors are needed, as we connect to the same registers as the existing SCADA system. The high granularity data is assessed at the edge for anomalies, using time series anomaly detection algorithms. We then synthesize the prediction into a health index that quantifies the recency and the frequency of the detected anomalies for the asset. The health index is then transmitted to a web-based application, where the user can configure thresholds for generating alerts based on the criticality of the asset. We demonstrate our solution in a case study, where the application was deployed using Schneider Electric's Customer First Digital Hub, to monitor a sewage pump station for blockages and other subtle deviations in operating patterns.

Annual Conference of the PHM SocietyVol. 16(1)
Schneider Electric (Germany) (DE)
Industry, innovation and infrastructure
Openalex Percentile: Top 49%
Anomaly Detection Techniques and Applications
0.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.