On the microdosimetric characterisation of the radiation quality of a carbon-ion beam and the effect of the target volume thickness

<i>Objective.</i>Microdosimetry is gaining increasing interest in particle therapy. Thanks to the advancements in microdosimeter technologies and the increasing number of experimental studies carried out in hadron therapy frameworks, it is proving to be a reliable experimental technique for radiation quality characterisation, quality assurance, and radiobiology studies. However, considering the variety of detectors used for microdosimetry, it is important to ensure the consistency of microdosimetric results measured with different types of microdosimeters.<i>Approach.</i>This work presents a novel multi-thickness microdosimeter and a methodology to characterise the radiation quality of a clinical carbon-ion beam. The novel device is a diamond detector made of three sensitive volumes (SVs) of different thicknesses: 2, 6 and 12<i>µ</i>m. The SVs, which operate simultaneously, were accurately aligned and laterally positioned within 3 mm. This alignment allowed for a comparison of the results with a negligible impact of the SVs alignment and their lateral positioning, ensuring the homogeneity of the measured radiation quality. An experimental campaign was carried out at MedAustron using a carbon-ion beam of typical clinical energy (284.7 MeV u<sup>-1</sup>).<i>Main results.</i>The measurement results allowed for a meticulous interpretation of its radiation quality, highlighting the effect of the SV thickness. The consistency of the microdosimetric spectra measured by detectors of different thicknesses is discussed by critically analysing the spectra and the differences observed.<i>Significance.</i>The methodology presented will be highly valuable for future experiments investigating the effects of the target volume size in radiobiology and could be easily adapted to the other particles employed in hadron therapy for clinical (i.e. protons) and for research purposes (e.g. helium, lithium and oxygen ions).

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-11-22
DOI
https://doi.org/10.1088/1361-6560/ad965e
Citations
5
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the microdosimetric characterisation of the radiation quality of a carbon-ion beam and the effect of the target volume thickness

Sandra Barna, G. Verona‐Rinati, C. Verona, Francesco ROMANO et al.
5 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
2.09
article

On the microdosimetric characterisation of the radiation quality of a carbon-ion beam and the effect of the target volume thickness

Sandra Barna, G. Verona‐Rinati, C. Verona, Francesco ROMANO, Giuseppe Schettino, Giulio Magrin, Gabriele Parisi, Cynthia Meouchi
article en
5 citations

Abstract

<i>Objective.</i>Microdosimetry is gaining increasing interest in particle therapy. Thanks to the advancements in microdosimeter technologies and the increasing number of experimental studies carried out in hadron therapy frameworks, it is proving to be a reliable experimental technique for radiation quality characterisation, quality assurance, and radiobiology studies. However, considering the variety of detectors used for microdosimetry, it is important to ensure the consistency of microdosimetric results measured with different types of microdosimeters.<i>Approach.</i>This work presents a novel multi-thickness microdosimeter and a methodology to characterise the radiation quality of a clinical carbon-ion beam. The novel device is a diamond detector made of three sensitive volumes (SVs) of different thicknesses: 2, 6 and 12<i>µ</i>m. The SVs, which operate simultaneously, were accurately aligned and laterally positioned within 3 mm. This alignment allowed for a comparison of the results with a negligible impact of the SVs alignment and their lateral positioning, ensuring the homogeneity of the measured radiation quality. An experimental campaign was carried out at MedAustron using a carbon-ion beam of typical clinical energy (284.7 MeV u<sup>-1</sup>).<i>Main results.</i>The measurement results allowed for a meticulous interpretation of its radiation quality, highlighting the effect of the SV thickness. The consistency of the microdosimetric spectra measured by detectors of different thicknesses is discussed by critically analysing the spectra and the differences observed.<i>Significance.</i>The methodology presented will be highly valuable for future experiments investigating the effects of the target volume size in radiobiology and could be easily adapted to the other particles employed in hadron therapy for clinical (i.e. protons) and for research purposes (e.g. helium, lithium and oxygen ions).

Physics in Medicine and BiologyVol. 69(24)
University of Rome Tor Vergata (IT), University of Applied Sciences Technikum Wien (AT), University of Vienna (AT), National Physical Laboratory (GB), TU Wien (AT), University of Pavia (IT), University of Surrey (GB), University of Catania (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Catania (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (IT), Policlinico Tor Vergata (IT), Universitätszahnklinik Wien (AT), MedAustron (AT), Medical University of Vienna (AT)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 12%
Radiation Therapy and Dosimetry
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.