Optical field modulation-enhanced cantilever sensor-based photoacoustic spectroscopy gas detection system

Abstract This study presents an approach to enhance the sensitivity of cantilever sensor-based photoacoustic (PA) spectroscopy gas detection systems through optical field modulation. Theoretical investigations into the mechanism and method of optical field modulation are followed by experimental validation. Acetylene is selected as the target molecule, with a near-infrared DFB LD laser serving as the light source. A dual-lens configuration was constructed to yield a better optical field distribution compared to the single-lens configuration. In the near-field of the laser, the setup of the dual-lens configuration has a better sensitivity than that of the single-lens setup, with a limit of detection reaching 0.52 μl l −1 . In the far-field of the laser, however, the PA signals are significantly lower than that of near-field measurements, indicating that far-field measurement is not preferred. The results can provide references to the sensitivity improvement of the PA spectroscopy-based gas sensing system.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-11-22
DOI
https://doi.org/10.1088/1402-4896/ad9644
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical field modulation-enhanced cantilever sensor-based photoacoustic spectroscopy gas detection system

Hongtu Cheng, Jie Feng, Zhi Fang, Yang Shen
Physica Scripta
Advanced Chemical Sensor Technologies
article

Optical field modulation-enhanced cantilever sensor-based photoacoustic spectroscopy gas detection system

Hongtu Cheng, Jie Feng, Zhi Fang, Yang Shen
article en

Abstract

Abstract This study presents an approach to enhance the sensitivity of cantilever sensor-based photoacoustic (PA) spectroscopy gas detection systems through optical field modulation. Theoretical investigations into the mechanism and method of optical field modulation are followed by experimental validation. Acetylene is selected as the target molecule, with a near-infrared DFB LD laser serving as the light source. A dual-lens configuration was constructed to yield a better optical field distribution compared to the single-lens configuration. In the near-field of the laser, the setup of the dual-lens configuration has a better sensitivity than that of the single-lens setup, with a limit of detection reaching 0.52 μl l −1 . In the far-field of the laser, however, the PA signals are significantly lower than that of near-field measurements, indicating that far-field measurement is not preferred. The results can provide references to the sensitivity improvement of the PA spectroscopy-based gas sensing system.

Physica ScriptaVol. 100(1)
Nanjing Tech University (CN), Wuhan University (CN)
China Postdoctoral Science Foundation
Affordable and clean energy
Openalex Percentile: Top 81%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.