Accurate acetabular cup placement using a smartphone-based digital alignment guide in total hip arthroplasty

Successful total hip arthroplasty (THA) requires accurate positioning of the acetabular cup. Although computed tomography (CT)-based navigation technology enables more accurate placement, most navigation systems are bulky, expensive, and often inaccessible due to cost and complexity. The purpose of this study was to introduce a smartphone-based digital cup alignment guide to improve placement accuracy and provide a cost-effective and accessible solution for THA. A smartphone application for acetabular cup placement in THA using built-in gyroscope and accelerometer sensors was developed. The application calculates and displays the cup inclination angle to ensure surgical accuracy. A prospective study was conducted to verify and validate the new guide by assessing the difference between the target pre-operative planned angles and the post-operative placement angles in 87 patients. Differences between the displayed intra-operative angles and the post-operative placement angles were compared between the new guide and CT-based navigation in 20 of the 87 cases. The post-operative cup inclination and anteversion angles were 40.4 ​± ​2.9° (range 35–47°) and 13.7 ​± ​4.4° (range 5–27°). Differences between the intra-operative target and post-operative cup inclination and anteversion angles were 1.8 ​± ​1.9° (range 0–7°) and 2.8 ​± ​2.5° (range 0–10°), respectively. The application demonstrated no significant difference in cup inclination and anteversion angle accuracy compared with CT-based navigation. The smartphone-based guide provides a practical alternative for cup placement in THA, especially in settings where CT-based navigation is not available. Challenges include the need to manage intra-operative pelvic alignment and rotational errors, which suggest room for improvement. However, it is a cost-effective and accessible tool that can improve the accuracy of acetabular cup placement in THA. • A smartphone-based digital cup alignment guide for total hip arthroplasty (THA) was developed. • It showed comparable accuracy to conventional navigation systems. • This application demonstrates the potential to enhance surgical precision. • It is also a cost-effective and universally accessible solution in THA.

Authors

Institutions

Publication Details

Journal
Journal of Joint Surgery and Research
Published
2024-11-22
DOI
https://doi.org/10.1016/j.jjoisr.2024.10.002
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate acetabular cup placement using a smartphone-based digital alignment guide in total hip arthroplasty

Yusuke Okanoue, Yuki Teranishi, Masahiko Ikeuchi, Junpei Dan et al.
Journal of Joint Surgery and Research
Orthopaedic implants and arthroplasty
article

Accurate acetabular cup placement using a smartphone-based digital alignment guide in total hip arthroplasty

Yusuke Okanoue, Yuki Teranishi, Masahiko Ikeuchi, Junpei Dan, Dai Ohira
article en

Abstract

Successful total hip arthroplasty (THA) requires accurate positioning of the acetabular cup. Although computed tomography (CT)-based navigation technology enables more accurate placement, most navigation systems are bulky, expensive, and often inaccessible due to cost and complexity. The purpose of this study was to introduce a smartphone-based digital cup alignment guide to improve placement accuracy and provide a cost-effective and accessible solution for THA. A smartphone application for acetabular cup placement in THA using built-in gyroscope and accelerometer sensors was developed. The application calculates and displays the cup inclination angle to ensure surgical accuracy. A prospective study was conducted to verify and validate the new guide by assessing the difference between the target pre-operative planned angles and the post-operative placement angles in 87 patients. Differences between the displayed intra-operative angles and the post-operative placement angles were compared between the new guide and CT-based navigation in 20 of the 87 cases. The post-operative cup inclination and anteversion angles were 40.4 ​± ​2.9° (range 35–47°) and 13.7 ​± ​4.4° (range 5–27°). Differences between the intra-operative target and post-operative cup inclination and anteversion angles were 1.8 ​± ​1.9° (range 0–7°) and 2.8 ​± ​2.5° (range 0–10°), respectively. The application demonstrated no significant difference in cup inclination and anteversion angle accuracy compared with CT-based navigation. The smartphone-based guide provides a practical alternative for cup placement in THA, especially in settings where CT-based navigation is not available. Challenges include the need to manage intra-operative pelvic alignment and rotational errors, which suggest room for improvement. However, it is a cost-effective and accessible tool that can improve the accuracy of acetabular cup placement in THA. • A smartphone-based digital cup alignment guide for total hip arthroplasty (THA) was developed. • It showed comparable accuracy to conventional navigation systems. • This application demonstrates the potential to enhance surgical precision. • It is also a cost-effective and universally accessible solution in THA.

Journal of Joint Surgery and ResearchVol. 3(1)
Uji Hospital (JP), Kōchi University (JP)
Openalex Percentile: Top 60%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.