ULTRATHIN SILVER-POLYSILOXANE-COATED PLATES FOR REVISION OF INFECTED FEMORAL NONUNION: FIRST RESULTS

Aim Aim of this study was to establish the first clinical results after implantation of ultrathin silver-polysiloxane-coated 1 plates in the treatment of infected non-union of the femoral shaft. Method As part of the REFECT study, a prospective, non-interventional analysis was conducted encompassing all patients who received internal stabilization with a silver-coated 1 plate from 01/2023 to 09/2024 as part of the treatment for infected non-union of the femur. Standardized clinical follow-ups including PROMs (WOMAC-Index, LEF-S, EQ-5D, VAS) and X-rays were performed 3, 6, 12 (and 24) months postoperatively. For comparison, a retrospective analysis of 76 patients with infected femoral non-union, who had received a stabilization with an uncoated plate in the past 10 years, was performed. Results The mean follow-up of the 8 included patients (mean bone defect: 3.6 cm) was 9 months (as of 04/24). Multiresistant bacteria were found in the intraoperative samples of 5 patients. The concentration of silver ions in blood serum reached a maximum of 0.014 mg/l in the laboratory controls. All patients showed a positive healing process with no sign of re-infection and no adverse procedure-associated events. Full weight bearing was achieved after an average of 4 months (n=6) with improved WOMAC-, LEF-S-, EQ-5D and VAS-score at 1-year FU. In the reference group (uncoated, mean FU: 3.5 years), there was a re-infection rate of 25 %, mostly in the first 2 years. Difficult-to-treat bacteria were detected in 22%, multiresistant Staph. epidermidis in 28% of cases. Conclusions The silver-coated 1 implants showed good biocompatibility with no evidence of procedure-associated complications. The use of silver-coated 1 implants could reduce the risk of re-infection. Further clinical data with longer follow-up are needed to assess the long-term value of the procedure.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2024-11-22
DOI
https://doi.org/10.1302/1358-992x.2024.19.062
Citations
1
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ULTRATHIN SILVER-POLYSILOXANE-COATED PLATES FOR REVISION OF INFECTED FEMORAL NONUNION: FIRST RESULTS

Arndt‐Peter Schulz, Karl‐Heinz Frosch, Birgitt Kowald, C. Grimme et al.
1 citations
Orthopaedic Proceedings
Orthopedic Infections and Treatments
0.57
article

ULTRATHIN SILVER-POLYSILOXANE-COATED PLATES FOR REVISION OF INFECTED FEMORAL NONUNION: FIRST RESULTS

Arndt‐Peter Schulz, Karl‐Heinz Frosch, Birgitt Kowald, C. Grimme, Maximilian Michael Mueller, Ulf-Joachim Gerlach, Rita Schoop-Schmetgens
article en
1 citations

Abstract

Aim Aim of this study was to establish the first clinical results after implantation of ultrathin silver-polysiloxane-coated 1 plates in the treatment of infected non-union of the femoral shaft. Method As part of the REFECT study, a prospective, non-interventional analysis was conducted encompassing all patients who received internal stabilization with a silver-coated 1 plate from 01/2023 to 09/2024 as part of the treatment for infected non-union of the femur. Standardized clinical follow-ups including PROMs (WOMAC-Index, LEF-S, EQ-5D, VAS) and X-rays were performed 3, 6, 12 (and 24) months postoperatively. For comparison, a retrospective analysis of 76 patients with infected femoral non-union, who had received a stabilization with an uncoated plate in the past 10 years, was performed. Results The mean follow-up of the 8 included patients (mean bone defect: 3.6 cm) was 9 months (as of 04/24). Multiresistant bacteria were found in the intraoperative samples of 5 patients. The concentration of silver ions in blood serum reached a maximum of 0.014 mg/l in the laboratory controls. All patients showed a positive healing process with no sign of re-infection and no adverse procedure-associated events. Full weight bearing was achieved after an average of 4 months (n=6) with improved WOMAC-, LEF-S-, EQ-5D and VAS-score at 1-year FU. In the reference group (uncoated, mean FU: 3.5 years), there was a re-infection rate of 25 %, mostly in the first 2 years. Difficult-to-treat bacteria were detected in 22%, multiresistant Staph. epidermidis in 28% of cases. Conclusions The silver-coated 1 implants showed good biocompatibility with no evidence of procedure-associated complications. The use of silver-coated 1 implants could reduce the risk of re-infection. Further clinical data with longer follow-up are needed to assess the long-term value of the procedure.

Orthopaedic ProceedingsVol. 106-B(SUPP_19)
Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE), BG Klinikum Hamburg (DE)
Good health and well-being
Openalex Percentile: Top 27%
Orthopedic Infections and Treatments
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.