EVALUATION OF A NEW POINT-OF-CARE APPROACH FOR SYNOVIAL FLUID CELL-FREE DNA QUANTIFICATION FOR PERIPROSTHETIC JOINT INFECTION DIAGNOSIS

Aim Periprosthetic joint infection (PJI) is one of the most frequent and devastating complications of total knee arthroplasty (TKA). Accurate diagnosis and proper treatment are essential to prevent functional loss and progression to systemic infection. However, the correct diagnosis of PJI is still a challenge since there is no accurate diagnostic method and the existing diagnostic criteria are based on serological, histological and microbiological tests that are imprecise and time-consuming. Recently, it was demonstrated that cell-free DNA is increased in the synovial fluid of patients with PJI. Therefore, this study aims to evaluate a new point-of-care methodology for quantifying free DNA in synovial fluid. Method A prospective study was carried out with patients undergoing TKA revision surgery, from whom it was possible to collect synovial fluid (SF) during the surgical procedure. Cell-free DNA quantification was performed directly from the SF, using a portable fluorimeter. Sensitivity, specificity and receiver operating characteristic (ROC) curve were calculated. Results Fifty-four patients were included in the study, of which 25 were diagnosed with PJI. Cell-free DNA levels measured immediately after collection were increased in the synovial fluid of patients with PJI (26.3 ± 14.8) in comparison with the uninfected group (4.6 ng/ml ± 3.8, p< 0.0001). The area under the receiver operating characteristic curve (AUC ROC) was 0.981 (95% CI 0.914 to 0.999). Conclusions From the results presented, we can conclude that the quantification of free DNA with a portable fluorimeter proved to be a test with high sensitivity and specificity for the diagnosis of PJI.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2024-11-22
DOI
https://doi.org/10.1302/1358-992x.2024.19.071
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF A NEW POINT-OF-CARE APPROACH FOR SYNOVIAL FLUID CELL-FREE DNA QUANTIFICATION FOR PERIPROSTHETIC JOINT INFECTION DIAGNOSIS

Ana Carolina Leal, Hugo Alexandre de Araújo Barros Cobra, Alan de Paula Mozella
Orthopaedic Proceedings
Orthopaedic implants and arthroplasty
article

EVALUATION OF A NEW POINT-OF-CARE APPROACH FOR SYNOVIAL FLUID CELL-FREE DNA QUANTIFICATION FOR PERIPROSTHETIC JOINT INFECTION DIAGNOSIS

Ana Carolina Leal, Hugo Alexandre de Araújo Barros Cobra, Alan de Paula Mozella
article en

Abstract

Aim Periprosthetic joint infection (PJI) is one of the most frequent and devastating complications of total knee arthroplasty (TKA). Accurate diagnosis and proper treatment are essential to prevent functional loss and progression to systemic infection. However, the correct diagnosis of PJI is still a challenge since there is no accurate diagnostic method and the existing diagnostic criteria are based on serological, histological and microbiological tests that are imprecise and time-consuming. Recently, it was demonstrated that cell-free DNA is increased in the synovial fluid of patients with PJI. Therefore, this study aims to evaluate a new point-of-care methodology for quantifying free DNA in synovial fluid. Method A prospective study was carried out with patients undergoing TKA revision surgery, from whom it was possible to collect synovial fluid (SF) during the surgical procedure. Cell-free DNA quantification was performed directly from the SF, using a portable fluorimeter. Sensitivity, specificity and receiver operating characteristic (ROC) curve were calculated. Results Fifty-four patients were included in the study, of which 25 were diagnosed with PJI. Cell-free DNA levels measured immediately after collection were increased in the synovial fluid of patients with PJI (26.3 ± 14.8) in comparison with the uninfected group (4.6 ng/ml ± 3.8, p< 0.0001). The area under the receiver operating characteristic curve (AUC ROC) was 0.981 (95% CI 0.914 to 0.999). Conclusions From the results presented, we can conclude that the quantification of free DNA with a portable fluorimeter proved to be a test with high sensitivity and specificity for the diagnosis of PJI.

Orthopaedic ProceedingsVol. 106-B(SUPP_19)
Instituto Nacional de Traumatologia e Ortopedia (BR)
Good health and well-being
Openalex Percentile: Top 60%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.