A bio-nano-engineered platform fabricated from cerium oxide-carbon nanoparticles stabilized with chitosan for label-free sensing of a lung cancer biomarker

Herein, we report a label-free cancer biosensor designed for carcinoembryonic antigen (CEA) detection using a nanohybrid comprising CeO<sub>2</sub> nanoparticles, carbon nanoparticles (CNPs), and chitosan (Ch). CeO<sub>2</sub> nanoparticles were prepared using a simple green synthesis process. A thin film of the CeO<sub>2</sub>-CNPs-Ch nanohybrid was formed on indium tin oxide (ITO)-coated glass plates that endowed a high surface area, excellent stability, and good adsorption for the efficient loading of CEA antibodies. Quantitative and selective determination of CEA antigen was achieved by immobilizing monoclonal CEA antibodies (anti-CEA) on the CeO<sub>2</sub>-CNPs-Ch/ITO platform. The electrochemical response of the anti-CEA/CeO<sub>2</sub>-CNPs-Ch/ITO immunoelectrode was evaluated in a label-free immunoassay format using differential pulse voltammetry (DPV). The response studies of immunoelectrodes indicated wider linearity with respect to the CEA concentration in the range of 0.05-100 ng mL<sup>-1</sup>. The electrochemical cancer biosensor exhibited a higher sensitivity of 22.40 μA cm<sup>-2</sup> per decade change in concentration along with storage stability for up to 35 days. The limit of detection (LOD) was 0.037 ng mL<sup>-1</sup>. Furthermore, this cancer biosensor exhibited good specificity and reproducibility. Thus, the proposed CeO<sub>2</sub>-CNPs-Ch nanocomposite-based platform provides an efficient method for the analysis of other antigen-antibody interactions and biomolecule detection. The efficacy of the anti-CEA/CeO<sub>2</sub>-CNPs-Ch/ITO immunoelectrode was further examined by measuring CEA levels in human serum.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2024-11-22
DOI
https://doi.org/10.1039/d4ay01535e
Citations
4
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A bio-nano-engineered platform fabricated from cerium oxide-carbon nanoparticles stabilized with chitosan for label-free sensing of a lung cancer biomarker

Shyam S. Pandey, Devendra Pratap Mishra, Jay Singh, Upendra Kumar Mishra et al.
4 citations
Analytical Methods
Advanced Nanomaterials in Catalysis
0.47
article

A bio-nano-engineered platform fabricated from cerium oxide-carbon nanoparticles stabilized with chitosan for label-free sensing of a lung cancer biomarker

Shyam S. Pandey, Devendra Pratap Mishra, Jay Singh, Upendra Kumar Mishra, Vishal Singh Chandel, Atul Kumar, Kshitij RB Singh, Saurabh Srivastava, Vivekanand Singh
article en
4 citations

Abstract

Herein, we report a label-free cancer biosensor designed for carcinoembryonic antigen (CEA) detection using a nanohybrid comprising CeO<sub>2</sub> nanoparticles, carbon nanoparticles (CNPs), and chitosan (Ch). CeO<sub>2</sub> nanoparticles were prepared using a simple green synthesis process. A thin film of the CeO<sub>2</sub>-CNPs-Ch nanohybrid was formed on indium tin oxide (ITO)-coated glass plates that endowed a high surface area, excellent stability, and good adsorption for the efficient loading of CEA antibodies. Quantitative and selective determination of CEA antigen was achieved by immobilizing monoclonal CEA antibodies (anti-CEA) on the CeO<sub>2</sub>-CNPs-Ch/ITO platform. The electrochemical response of the anti-CEA/CeO<sub>2</sub>-CNPs-Ch/ITO immunoelectrode was evaluated in a label-free immunoassay format using differential pulse voltammetry (DPV). The response studies of immunoelectrodes indicated wider linearity with respect to the CEA concentration in the range of 0.05-100 ng mL<sup>-1</sup>. The electrochemical cancer biosensor exhibited a higher sensitivity of 22.40 μA cm<sup>-2</sup> per decade change in concentration along with storage stability for up to 35 days. The limit of detection (LOD) was 0.037 ng mL<sup>-1</sup>. Furthermore, this cancer biosensor exhibited good specificity and reproducibility. Thus, the proposed CeO<sub>2</sub>-CNPs-Ch nanocomposite-based platform provides an efficient method for the analysis of other antigen-antibody interactions and biomolecule detection. The efficacy of the anti-CEA/CeO<sub>2</sub>-CNPs-Ch/ITO immunoelectrode was further examined by measuring CEA levels in human serum.

Analytical MethodsVol. 17(2)
Dr. A.P.J. Abdul Kalam Technical University (IN), Kyushu Institute of Technology (JP), Banaras Hindu University (IN)
Openalex Percentile: Top 37%
Advanced Nanomaterials in Catalysis
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.