Long-range strain sensing system using a frequency-locked π-shifted grating

We present a passive, all-fiber strain sensing system capable of measuring strain over 75 km using a diode laser locked to a π-shifted grating. The local strain measurement is extracted from the feedback signal sent to the laser for frequency stabilization, thereby reducing the baseline acoustic noise level. Strain variations at frequencies above 10 kHz were obtained from the intensity of the amplified return light. Using both the feedback signal and the light intensity measurement, the strain was measured between DC and 100 kHz, making sound and music recording possible at very long distances. At 10 Hz, the sensitivity was 5.27 mV/µɛ and a minimal detectable strain of <i>dɛ</i><sub>min</sub> = 23 nɛ was obtained. The strain sensing range was approximately 28 dB, from about 30 nɛ to 20 µɛ.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-11-22
DOI
https://doi.org/10.1364/oe.538786
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-range strain sensing system using a frequency-locked π-shifted grating

Deniz Aydın, Hans‐Peter Loock, Swapnil Daxini, Xijia Gu et al.
1 citations
Optics Express
Advanced Fiber Optic Sensors
0.21
article

Long-range strain sensing system using a frequency-locked π-shifted grating

Deniz Aydın, Hans‐Peter Loock, Swapnil Daxini, Xijia Gu, Jack A. Barnes, Arthur Giron
article en
1 citations

Abstract

We present a passive, all-fiber strain sensing system capable of measuring strain over 75 km using a diode laser locked to a π-shifted grating. The local strain measurement is extracted from the feedback signal sent to the laser for frequency stabilization, thereby reducing the baseline acoustic noise level. Strain variations at frequencies above 10 kHz were obtained from the intensity of the amplified return light. Using both the feedback signal and the light intensity measurement, the strain was measured between DC and 100 kHz, making sound and music recording possible at very long distances. At 10 Hz, the sensitivity was 5.27 mV/µɛ and a minimal detectable strain of <i>dɛ</i><sub>min</sub> = 23 nɛ was obtained. The strain sensing range was approximately 28 dB, from about 30 nɛ to 20 µɛ.

Optics ExpressVol. 33(3)
Queen's University (CA), University of Victoria (CA), Toronto Metropolitan University (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 46%
Advanced Fiber Optic Sensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.