Factors Influencing Differences Between Computed and Measured Ground Resistance Values for Horizontal Tape Electrodes

This paper investigates the steady-state resistance (RDC) of copper tape electrodes across eight configurations. The study evaluates both field measurements and simulations using CDEGS at two distinct sites with varying soil characteristics. It emphasizes the impact of electrode size, installation sequence, and soil disturbance caused by sequential installations. Specifically, the results reveal that the first configuration, which maintained a 100% tape-to-trench ratio with no disturbance, yielded computed values within the measured range at both sites. Subsequent configurations demonstrated varying degrees of soil disturbance, affecting RDC values, particularly in high-resistivity conditions. At the low-resistivity Site 1, as the tape-to-trench ratio increased, discrepancies between measured and computed RDC values decreased, highlighting a strong dependency on electrode size and soil cohesion after backfilling. In contrast, at the high-resistivity Site 2, RDC values remained relatively stable with increasing tape-to-trench ratio, likely due to lower soil cohesion and higher air void presence. These findings underscore the importance of considering soil disturbance effects in computational models to enhance the accuracy of RDC predictions and optimize grounding performance.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-22
DOI
https://doi.org/10.3390/en17235845
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Influencing Differences Between Computed and Measured Ground Resistance Values for Horizontal Tape Electrodes

Usman Muhammad, Fazlul Aman, Normiza Mohamad Nor, N. Ahmad
Energies
Smart Materials for Construction
article

Factors Influencing Differences Between Computed and Measured Ground Resistance Values for Horizontal Tape Electrodes

Usman Muhammad, Fazlul Aman, Normiza Mohamad Nor, N. Ahmad
article en

Abstract

This paper investigates the steady-state resistance (RDC) of copper tape electrodes across eight configurations. The study evaluates both field measurements and simulations using CDEGS at two distinct sites with varying soil characteristics. It emphasizes the impact of electrode size, installation sequence, and soil disturbance caused by sequential installations. Specifically, the results reveal that the first configuration, which maintained a 100% tape-to-trench ratio with no disturbance, yielded computed values within the measured range at both sites. Subsequent configurations demonstrated varying degrees of soil disturbance, affecting RDC values, particularly in high-resistivity conditions. At the low-resistivity Site 1, as the tape-to-trench ratio increased, discrepancies between measured and computed RDC values decreased, highlighting a strong dependency on electrode size and soil cohesion after backfilling. In contrast, at the high-resistivity Site 2, RDC values remained relatively stable with increasing tape-to-trench ratio, likely due to lower soil cohesion and higher air void presence. These findings underscore the importance of considering soil disturbance effects in computational models to enhance the accuracy of RDC predictions and optimize grounding performance.

EnergiesVol. 17(23)
Multimedia University (MY)
Telekom Malaysia Berhad
Life in Land
Openalex Percentile: Top 87%
Smart Materials for Construction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Factors Influencing Differences Between Computed and Measured Ground Resistance Values for Horizontal Tape Electrodes — Usman Muhammad, Fazlul Aman, et al. · Energies (2024) | TGRS Research Map | TGRS