Worst-Case Voltage Droop Using Peak Distortion Analysis
This paper introduces a method for calculating the worst-case voltage droops experienced by a power distribution network. Through peak distortion analysis, each port in a multiport model is stimulated to produce patterns that will result in a large voltage swing at a selected observation point. This approach enables power integrity engineers to anticipate worst-case scenarios at the beginning of the design process and initiate the optimization of power delivery. The methodology is demonstrated using a real system as an example.
Authors
- Mohamed Sahouli (ORCID: https://orcid.org/0000-0003-0612-4285)
- Gerry Talbot
- Iftikhar Ali (ORCID: https://orcid.org/0000-0002-8406-337X)
- David ReinaMendivil
Institutions
- Advanced Micro Devices (Canada) (CA)
Publication Details
- Published
- 2024-10-06
- DOI
- https://doi.org/10.1109/epeps61853.2024.10754100
- Primary Topic
- Low-power high-performance VLSI design
- Type
- article
- Field-Weighted Citation Impact
- 0.00