An artificial intelligence-based screening tool for orthognathic surgery using MKG angle in lateral cephalograms

Objectives: This study aimed to develop a clinical decision support system utilizing the MKG angle – derived from points M, K, and G – as a novel neural network parameter for evaluating sagittal maxillo-mandibular discrepancy. This system serves as a pre-operative screening tool for predicting the need for orthognathic surgery. Material and Methods: This retrospective study collected 494 digital lateral cephalograms. MKG angle values extracted from these cephalograms were analyzed using a Keypoint Region-based Convolutional Neural Network integrated with Detectron2 for object detection. Analysis was conducted using Keras software to facilitate decision-making regarding orthognathic surgery. The model’s output ranged from 0 to 1, with values closer to 1 indicating a stronger recommendation for orthognathic surgery. A training loss graph was used to monitor the model’s performance over epochs, while a confusion matrix evaluated the model’s accuracy and predictive capabilities. Results: The training loss value for the object detection model was 3.0510. Model performance was further evaluated using metrics such as root mean square error (RMSE) and percentage of detected joints (PDJ). The RMSE was measured at 2.68 pixels, while the PDJ, with a threshold of 0.05, achieved a value of 0.99, indicating a high level of accuracy. The developed system achieved an orthognathic surgery diagnosis accuracy of 70.41%, with a training loss value of 0.6163. The evaluation revealed instances of misdiagnosis; out of 98 cases, 29 were identified as misdiagnosed through a confusion matrix. The model’s sensitivity and specificity were measured at 72.5% and 68.97%, respectively. Conclusion: A supplementary tool for orthognathic screening, utilizing two-dimensional digital lateral cephalometry images and MKG angle as a parameter, was developed by merging a neural network model with clinical decision-making.

Authors

Institutions

Publication Details

Journal
APOS Trends in Orthodontics
Published
2024-11-20
DOI
https://doi.org/10.25259/apos_153_2024
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An artificial intelligence-based screening tool for orthognathic surgery using MKG angle in lateral cephalograms

Bhornsawan Thanathornwong, Somchai Manopatanakul, Sasipa Thiradilok, Natthaya Limcharoen
APOS Trends in Orthodontics
Dental Radiography and Imaging
article

An artificial intelligence-based screening tool for orthognathic surgery using MKG angle in lateral cephalograms

Bhornsawan Thanathornwong, Somchai Manopatanakul, Sasipa Thiradilok, Natthaya Limcharoen
article en

Abstract

Objectives: This study aimed to develop a clinical decision support system utilizing the MKG angle – derived from points M, K, and G – as a novel neural network parameter for evaluating sagittal maxillo-mandibular discrepancy. This system serves as a pre-operative screening tool for predicting the need for orthognathic surgery. Material and Methods: This retrospective study collected 494 digital lateral cephalograms. MKG angle values extracted from these cephalograms were analyzed using a Keypoint Region-based Convolutional Neural Network integrated with Detectron2 for object detection. Analysis was conducted using Keras software to facilitate decision-making regarding orthognathic surgery. The model’s output ranged from 0 to 1, with values closer to 1 indicating a stronger recommendation for orthognathic surgery. A training loss graph was used to monitor the model’s performance over epochs, while a confusion matrix evaluated the model’s accuracy and predictive capabilities. Results: The training loss value for the object detection model was 3.0510. Model performance was further evaluated using metrics such as root mean square error (RMSE) and percentage of detected joints (PDJ). The RMSE was measured at 2.68 pixels, while the PDJ, with a threshold of 0.05, achieved a value of 0.99, indicating a high level of accuracy. The developed system achieved an orthognathic surgery diagnosis accuracy of 70.41%, with a training loss value of 0.6163. The evaluation revealed instances of misdiagnosis; out of 98 cases, 29 were identified as misdiagnosed through a confusion matrix. The model’s sensitivity and specificity were measured at 72.5% and 68.97%, respectively. Conclusion: A supplementary tool for orthognathic screening, utilizing two-dimensional digital lateral cephalometry images and MKG angle as a parameter, was developed by merging a neural network model with clinical decision-making.

APOS Trends in OrthodonticsVol. 15
Mahidol University (TH), Srinakharinwirot University (TH)
Peace, Justice and strong institutions
Openalex Percentile: Top 68%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.