Experimental study on stability and heat transfer characteristics of separated heat pipe with a compressible volume condenser

A novel Separated Heat Pipe (SHP) system incorporating two magnetic spheres (SHPMS) was proposed for power generation (US Patent 11365653B2, 2022) using low-grade thermal energy, or offering both reliable emergency power and efficient heat transfer for spent fuel pools. This paper reports the experimental investigation on flow and heat transfer characteristics of the SHP, providing a foundation for the R&D of SHPMS. The SHP system features a unique shell-and-tube condenser structure, where the tube side serves as the cooling coil, while the shell side functions as the condenser chamber, with the dual roles of liquid storage and surge tank. The study researched the stability and heat transfer performance of the SHP under various parameters, including filling ratios ranging from 17 % to 98 %, cooling temperatures between 14 °C and 22 °C, and system pressures from 630 to 830 kPa. Analysis of instantaneous temperature, pressure, and flow patterns reveals the absence of high-frequency oscillations or alternating flow patterns, indicating that the condenser's condensing chamber may eliminate the instability in the SHP. Comparative analysis of the heat transfer coefficient and thermal resistance indicates that higher filling ratios and system pressures impair heat transfer performance, with optimal results at lower filling ratios (17 %–55 %) and pressure (630 kPa), where the higher heat transfer coefficient and lower thermal resistance were observed. Cooling temperatures showed little impact on heat transfer, allowing it to be chosen based on safety and energy efficiency needs. This study provides a new perspective on SHP systems with compressible volume condenser, offering a potential solution to address the instability challenges of SHP and the selection of operation parameters.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-11-21
DOI
https://doi.org/10.1016/j.csite.2024.105511
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on stability and heat transfer characteristics of separated heat pipe with a compressible volume condenser

Jinle Zhao, Fan Feng, Teng Wang, Tao Zhang et al.
1 citations
Case Studies in Thermal Engineering
Heat Transfer and Boiling Studies
0.21
article

Experimental study on stability and heat transfer characteristics of separated heat pipe with a compressible volume condenser

Jinle Zhao, Fan Feng, Teng Wang, Tao Zhang, Qincheng Bi
article en
1 citations

Abstract

A novel Separated Heat Pipe (SHP) system incorporating two magnetic spheres (SHPMS) was proposed for power generation (US Patent 11365653B2, 2022) using low-grade thermal energy, or offering both reliable emergency power and efficient heat transfer for spent fuel pools. This paper reports the experimental investigation on flow and heat transfer characteristics of the SHP, providing a foundation for the R&D of SHPMS. The SHP system features a unique shell-and-tube condenser structure, where the tube side serves as the cooling coil, while the shell side functions as the condenser chamber, with the dual roles of liquid storage and surge tank. The study researched the stability and heat transfer performance of the SHP under various parameters, including filling ratios ranging from 17 % to 98 %, cooling temperatures between 14 °C and 22 °C, and system pressures from 630 to 830 kPa. Analysis of instantaneous temperature, pressure, and flow patterns reveals the absence of high-frequency oscillations or alternating flow patterns, indicating that the condenser's condensing chamber may eliminate the instability in the SHP. Comparative analysis of the heat transfer coefficient and thermal resistance indicates that higher filling ratios and system pressures impair heat transfer performance, with optimal results at lower filling ratios (17 %–55 %) and pressure (630 kPa), where the higher heat transfer coefficient and lower thermal resistance were observed. Cooling temperatures showed little impact on heat transfer, allowing it to be chosen based on safety and energy efficiency needs. This study provides a new perspective on SHP systems with compressible volume condenser, offering a potential solution to address the instability challenges of SHP and the selection of operation parameters.

Case Studies in Thermal EngineeringVol. 64
North China Electric Power University (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 50%
Heat Transfer and Boiling Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.