A Validated LC-MS/MS Method for Determination at Trace Level of Nitrosamine Impurities in Doxofylline API

Background The FDA looked at popular amine-based API synthesis processes and found that these processes might additionally introduce nitrosamine-hazardous substances. The current method describes trace-level quantification of Nitrosamine impurities (NDEA, NDIPA, NDIPA, NEIPA, NMPA, NDBA, NDMA and NMBA) in the Doxofylline API. Materials and Methods With the help of Waters® ACQUITY® UPLC BEH C18 (150x4.6 mm, 5 μm) and a 0.8 mL/min flow, a gradient programme (0.1%v/v formic acid and methanol) continuing for 14 min was used to achieve separation. Using Multiple Reaction Monitoring (MRM), all nitrosamine impurities were ionized and measured in the positive polarity mode of APCI. Results Protonated molecular ions (M+H)+ were acquainted at: m/z 75 (parent), m/z 58 (product), m/z 103 (parent), m/z 47 (product), m/z 131 (parent), m/z 89 (product), m/z 117.1 (parent), m/z 74.8 (product), m/z 147.1 (parent), m/z 117 (product), m/z 137 (parent), m/z 66 (product), m/z 159 (parent), m/z 103 (product), m/z 267.2 (parent), m/z 181.1 (product), respectively, for NDMA, NDEA, NDIPA, NEIPA, NMBA, NMPA, NDBA and Doxofylline, with their retention times observed as 4.04, 6.83, 8.97, 7.98, 4.92, 9.25, 11.06 and 7.15 min, respectively. Conclusion The coefficient of determination (r2) for individual impurities was found to be between 0.996 and 1.000. S/N method was used to establish limits of detection and quantification, which turned out as 0.0040 μg/mL-0.0174 μg/mL and 0.0060 μg/mL-0.0262 μg/mL, respectively. Each of the validation parameters falls within the allowed ranges as per USP<1225>.

Authors

Publication Details

Journal
Indian Journal of Pharmaceutical Education and Research
Published
2024-11-18
DOI
https://doi.org/10.5530/ijper.58.4s.121
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Validated LC-MS/MS Method for Determination at Trace Level of Nitrosamine Impurities in Doxofylline API

Narender Malothu, Swetha Sri Remidicherla, Guntupalli Chakravarthi
2 citations
Indian Journal of Pharmaceutical Education and Research
Analytical Chemistry and Sensors
0.58
article

A Validated LC-MS/MS Method for Determination at Trace Level of Nitrosamine Impurities in Doxofylline API

Narender Malothu, Swetha Sri Remidicherla, Guntupalli Chakravarthi
article en
2 citations

Abstract

Background The FDA looked at popular amine-based API synthesis processes and found that these processes might additionally introduce nitrosamine-hazardous substances. The current method describes trace-level quantification of Nitrosamine impurities (NDEA, NDIPA, NDIPA, NEIPA, NMPA, NDBA, NDMA and NMBA) in the Doxofylline API. Materials and Methods With the help of Waters® ACQUITY® UPLC BEH C18 (150x4.6 mm, 5 μm) and a 0.8 mL/min flow, a gradient programme (0.1%v/v formic acid and methanol) continuing for 14 min was used to achieve separation. Using Multiple Reaction Monitoring (MRM), all nitrosamine impurities were ionized and measured in the positive polarity mode of APCI. Results Protonated molecular ions (M+H)+ were acquainted at: m/z 75 (parent), m/z 58 (product), m/z 103 (parent), m/z 47 (product), m/z 131 (parent), m/z 89 (product), m/z 117.1 (parent), m/z 74.8 (product), m/z 147.1 (parent), m/z 117 (product), m/z 137 (parent), m/z 66 (product), m/z 159 (parent), m/z 103 (product), m/z 267.2 (parent), m/z 181.1 (product), respectively, for NDMA, NDEA, NDIPA, NEIPA, NMBA, NMPA, NDBA and Doxofylline, with their retention times observed as 4.04, 6.83, 8.97, 7.98, 4.92, 9.25, 11.06 and 7.15 min, respectively. Conclusion The coefficient of determination (r2) for individual impurities was found to be between 0.996 and 1.000. S/N method was used to establish limits of detection and quantification, which turned out as 0.0040 μg/mL-0.0174 μg/mL and 0.0060 μg/mL-0.0262 μg/mL, respectively. Each of the validation parameters falls within the allowed ranges as per USP<1225>.

Indian Journal of Pharmaceutical Education and ResearchVol. 58(4s)
Zero hunger
Openalex Percentile: Top 36%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.