Film Cooling and Thermal Performances of a Blade Tip Winglet Operated in an Annular Test Rig and a Test Gas Turbine Power Plant

Abstract This paper investigates the film cooling performances and thermal behavior of a blade tip winglet, which was initially investigated in a 1.5-stage experimental axial turbine facility and subsequently also tested in a gas turbine power plant. The adiabatic film cooling effectiveness was measured in the rotating 1.5-stage axial turbine facility, whereas in the gas turbine power plant, the tip winglet had active internal cooling coupled to the airfoil and winglet film cooling system. For both test facilities, the tip winglet consisted of several fan-shaped diffuser cooling holes, which were distributed in various regions of the tip winglet and airfoil. The pressure-sensitive paint method was employed to measure the film cooling effectiveness in the 1.5-stage test rig, which was conducted for two tip clearances and a range of blowing ratios. The tip winglet in the gas turbine test power plant was operated for a long duration and under various gas turbine steady-state and transient operating conditions. The blade and tip metal temperatures were measured with embedded thermocrystal sensors and thermocouples for a wide range of operating conditions. Measured local film cooling distributions from the 1.5-stage experimental turbine indicated that it was strongly dependent on the coolant blowing ratios but relatively insensitive to the tip clearances and coolant-to-hot gas density ratio. The measurements also indicated that there was reasonably good coverage of film cooling in large areas of the winglet cavity floor and pressure and suction side tip rims. Metal temperature measurements at various locations of the tip winglet from the gas turbine power plant tests, also indicated that the measured values were within the expected ranges of the predicted metal temperatures.

Authors

Institutions

Publication Details

Journal
Journal of Turbomachinery
Published
2024-11-21
DOI
https://doi.org/10.1115/1.4067237
Citations
3
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
3.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Film Cooling and Thermal Performances of a Blade Tip Winglet Operated in an Annular Test Rig and a Test Gas Turbine Power Plant

M. Henze, Manuel Wilhelm, Heinz-Peter Schiffer, Shailendra Naik
3 citations
Journal of Turbomachinery
Turbomachinery Performance and Optimization
3.90
article

Film Cooling and Thermal Performances of a Blade Tip Winglet Operated in an Annular Test Rig and a Test Gas Turbine Power Plant

M. Henze, Manuel Wilhelm, Heinz-Peter Schiffer, Shailendra Naik
article en
3 citations

Abstract

Abstract This paper investigates the film cooling performances and thermal behavior of a blade tip winglet, which was initially investigated in a 1.5-stage experimental axial turbine facility and subsequently also tested in a gas turbine power plant. The adiabatic film cooling effectiveness was measured in the rotating 1.5-stage axial turbine facility, whereas in the gas turbine power plant, the tip winglet had active internal cooling coupled to the airfoil and winglet film cooling system. For both test facilities, the tip winglet consisted of several fan-shaped diffuser cooling holes, which were distributed in various regions of the tip winglet and airfoil. The pressure-sensitive paint method was employed to measure the film cooling effectiveness in the 1.5-stage test rig, which was conducted for two tip clearances and a range of blowing ratios. The tip winglet in the gas turbine test power plant was operated for a long duration and under various gas turbine steady-state and transient operating conditions. The blade and tip metal temperatures were measured with embedded thermocrystal sensors and thermocouples for a wide range of operating conditions. Measured local film cooling distributions from the 1.5-stage experimental turbine indicated that it was strongly dependent on the coolant blowing ratios but relatively insensitive to the tip clearances and coolant-to-hot gas density ratio. The measurements also indicated that there was reasonably good coverage of film cooling in large areas of the winglet cavity floor and pressure and suction side tip rims. Metal temperature measurements at various locations of the tip winglet from the gas turbine power plant tests, also indicated that the measured values were within the expected ranges of the predicted metal temperatures.

Journal of TurbomachineryVol. 147(2)
Merck KGaA, Darmstadt (Germany) (DE), Ansaldo (Italy) (IT), Technische Universität Darmstadt (DE), Weber and Weber (Germany) (DE)
Bundesministerium für Wirtschaft und Energie
Affordable and clean energy
Openalex Percentile: Top 6%
Turbomachinery Performance and Optimization
3.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.