Accuracy Evaluation of a Three-Dimensional Face Reconstruction Model Based on the Hifi3D Face Model and Clinical Two-Dimensional Images

Three-dimensional (3D) facial models have been increasingly applied in orthodontics, orthognathic surgery, and various medical fields. This study proposed an approach to reconstructing 3D facial models from standard orthodontic frontal and lateral images, providing an efficient way to expand 3D databases. A total of 23 participants (average age 20.70 ± 5.36 years) were enrolled. Based on the Hifi3D face model, 3D reconstructions were generated and compared with corresponding face scans to evaluate their accuracy. Root mean square error (RMSE) values were calculated for the entire face, nine specific facial regions, and eight anatomical landmarks. Clinical feasibility was further assessed by comparing six angular and thirteen linear measurements between the reconstructed and scanned models. The RMSE of the reconstruction model was 2.00 ± 0.38 mm (95% CI: 1.84-2.17 mm). High accuracy was achieved for the forehead, nose, upper lip, paranasal region, and right cheek (mean RMSE < 2 mm). The forehead area showed the smallest deviation, at 1.52 ± 0.88 mm (95% CI: 1.14-1.90 mm). In contrast, the lower lip, chin, and left cheek exhibited average RMSEs exceeding 2 mm. The mean deviation across landmarks was below 2 mm, with the Prn displaying the smallest error at 1.18 ± 1.10 mm (95% CI: 0.71-1.65 mm). The largest discrepancies were observed along the Z-axis (Z > Y > X). Significant differences (<i>p</i> < 0.05) emerged between groups in the nasolabial, nasal, and nasofrontal angles, while the other 13 linear and 3 angular measurements showed no statistical differences (<i>p</i> > 0.05). This study explored the feasibility of reconstructing accurate 3D models from 2D photos. Compared to facial scan models, the Hifi3D face model demonstrated a 2 mm deviation, with potential for enriching 3D databases for subjective evaluations, patient education, and communication. However, caution is advised when applying this model to clinical measurements, especially angle assessments.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-11-21
DOI
https://doi.org/10.3390/bioengineering11121174
Citations
2
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Evaluation of a Three-Dimensional Face Reconstruction Model Based on the Hifi3D Face Model and Clinical Two-Dimensional Images

Yanheng Zhou, Jianglong Nie, Shuo Wang, Bochun Mao et al.
2 citations
Bioengineering
Orthodontics and Dentofacial Orthopedics
0.80
article

Accuracy Evaluation of a Three-Dimensional Face Reconstruction Model Based on the Hifi3D Face Model and Clinical Two-Dimensional Images

Yanheng Zhou, Jianglong Nie, Shuo Wang, Bochun Mao, Jiayi Liu, Dawei Liu, Yujia Xiao
article en
2 citations

Abstract

Three-dimensional (3D) facial models have been increasingly applied in orthodontics, orthognathic surgery, and various medical fields. This study proposed an approach to reconstructing 3D facial models from standard orthodontic frontal and lateral images, providing an efficient way to expand 3D databases. A total of 23 participants (average age 20.70 ± 5.36 years) were enrolled. Based on the Hifi3D face model, 3D reconstructions were generated and compared with corresponding face scans to evaluate their accuracy. Root mean square error (RMSE) values were calculated for the entire face, nine specific facial regions, and eight anatomical landmarks. Clinical feasibility was further assessed by comparing six angular and thirteen linear measurements between the reconstructed and scanned models. The RMSE of the reconstruction model was 2.00 ± 0.38 mm (95% CI: 1.84-2.17 mm). High accuracy was achieved for the forehead, nose, upper lip, paranasal region, and right cheek (mean RMSE < 2 mm). The forehead area showed the smallest deviation, at 1.52 ± 0.88 mm (95% CI: 1.14-1.90 mm). In contrast, the lower lip, chin, and left cheek exhibited average RMSEs exceeding 2 mm. The mean deviation across landmarks was below 2 mm, with the Prn displaying the smallest error at 1.18 ± 1.10 mm (95% CI: 0.71-1.65 mm). The largest discrepancies were observed along the Z-axis (Z > Y > X). Significant differences (<i>p</i> < 0.05) emerged between groups in the nasolabial, nasal, and nasofrontal angles, while the other 13 linear and 3 angular measurements showed no statistical differences (<i>p</i> > 0.05). This study explored the feasibility of reconstructing accurate 3D models from 2D photos. Compared to facial scan models, the Hifi3D face model demonstrated a 2 mm deviation, with potential for enriching 3D databases for subjective evaluations, patient education, and communication. However, caution is advised when applying this model to clinical measurements, especially angle assessments.

BioengineeringVol. 11(12)
Peking University (CN)
National Natural Science Foundation of China, Sichuan University, Peking University, State Key Laboratory of Oral Disease, Young Scientists Fund
Quality Education
Openalex Percentile: Top 30%
Orthodontics and Dentofacial Orthopedics
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.