Ultra-wide band near-infrared (NIR) optical thermometry (12–673 K) performance enhanced by Stark sublevel splitting in Er<sup>3+</sup> ions near the first biological window in the PbZr<sub>0.53</sub>Ti<sub>0.47</sub>O<sub>3</sub>:Er<sup>3+</sup>/Yb<s

The fluorescence intensity ratio (FIR) approach, which relies on thermally coupled levels (TCLs), is significantly important for optical thermometry at room temperature and above, but was found to be impractical for low temperature sensing due to limited population density (thermal) or lack of spectrum at extremely low temperatures. Herein, we report a wide temperature range (12-673 K) sensing capability of the PbZr<sub>0.53</sub>Ti<sub>0.47</sub>O<sub>3</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> (C1:PZT) phosphor utilising the bandwidth of Stark sublevel split near-infrared (NIR) emission bands as one sensing parameter and FIR as another. Motivated by our previous studies on upconversion (UC) and the promising thermometry performance of the C1:PZT phosphor for real time nanothermometer monitoring (using visible TCLs), this work extends to the same thermometry application using UC-NIR emission as TCLs. The temperature-dependent UC spectra were measured across the ranges of 12-313 K and 313-673 K under 980 nm excitation, and their sensing capabilities were thoroughly evaluated. An enveloped single emission band, comprising multiple peaks in the NIR region, was observed and subsequently deconvoluted using Gaussian fitting. These individual peaks were analyzed in relation to Stark sublevel splitting, which was particularly evident at 12 K, and the variations in their full width at half maximum (FWHM) were compared across temperatures up to 313 K. Based on the temperature-dependent bandwidth, two prominent peaks ∼11 655 cm<sup>-1</sup> (858 nm) and 11 454 cm<sup>-1</sup> (873 nm), were identified as TCL levels, and a sensitivity (<i>S</i><sub>r</sub>) of 0.68 ± 0.01% K<sup>-1</sup> at 673 K was observed, making it a suitable thermometer for reading low temperatures using NIR bands.

Authors

Institutions

Publication Details

Journal
Physical Chemistry Chemical Physics
Published
2024-11-21
DOI
https://doi.org/10.1039/d4cp03125c
Citations
5
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.59

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-wide band near-infrared (NIR) optical thermometry (12–673 K) performance enhanced by Stark sublevel splitting in Er3+ ions near the first biological window in the PbZr0.53Ti0.47O3:Er3+/Yb<s

Hendrik Christoffel Swart, Prasenjit Prasad Sukul, Yadvendra Singh
5 citations
Physical Chemistry Chemical Physics
Luminescence Properties of Advanced Materials
0.59
article

Ultra-wide band near-infrared (NIR) optical thermometry (12–673 K) performance enhanced by Stark sublevel splitting in Er3+ ions near the first biological window in the PbZr0.53Ti0.47O3:Er3+/Yb<s

Hendrik Christoffel Swart, Prasenjit Prasad Sukul, Yadvendra Singh
article en
5 citations

Abstract

The fluorescence intensity ratio (FIR) approach, which relies on thermally coupled levels (TCLs), is significantly important for optical thermometry at room temperature and above, but was found to be impractical for low temperature sensing due to limited population density (thermal) or lack of spectrum at extremely low temperatures. Herein, we report a wide temperature range (12-673 K) sensing capability of the PbZr<sub>0.53</sub>Ti<sub>0.47</sub>O<sub>3</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> (C1:PZT) phosphor utilising the bandwidth of Stark sublevel split near-infrared (NIR) emission bands as one sensing parameter and FIR as another. Motivated by our previous studies on upconversion (UC) and the promising thermometry performance of the C1:PZT phosphor for real time nanothermometer monitoring (using visible TCLs), this work extends to the same thermometry application using UC-NIR emission as TCLs. The temperature-dependent UC spectra were measured across the ranges of 12-313 K and 313-673 K under 980 nm excitation, and their sensing capabilities were thoroughly evaluated. An enveloped single emission band, comprising multiple peaks in the NIR region, was observed and subsequently deconvoluted using Gaussian fitting. These individual peaks were analyzed in relation to Stark sublevel splitting, which was particularly evident at 12 K, and the variations in their full width at half maximum (FWHM) were compared across temperatures up to 313 K. Based on the temperature-dependent bandwidth, two prominent peaks ∼11 655 cm<sup>-1</sup> (858 nm) and 11 454 cm<sup>-1</sup> (873 nm), were identified as TCL levels, and a sensitivity (<i>S</i><sub>r</sub>) of 0.68 ± 0.01% K<sup>-1</sup> at 673 K was observed, making it a suitable thermometer for reading low temperatures using NIR bands.

Physical Chemistry Chemical PhysicsVol. 27(1)
Oregon State University (US), University of the Free State (ZA)
National Research Foundation, Universiteit van die Vrystaat
Openalex Percentile: Top 33%
Luminescence Properties of Advanced Materials
0.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.