Borehole Optical Fibre Distributed Temperature Sensing vs. Manual Temperature Logging for Geothermal Condition Assessment: Results of the OptiSGE Project

Geothermal energy is a crucial component contributing to the development of local thermal energy systems as a carbon-neutral and reliable energy source. Insights into its availability derive from knowledge of geology, hydrogeology and the thermal regime of the subsurface. This expertise helps to locate and monitor geothermal installations as well as observe diverse aspects of natural and man-made thermal effects. Temperature measurements were performed in hydrogeological boreholes in south-western Poland using two methods, i.e., manual temperature logging and optical fibre distributed temperature sensing (OF DTS). It was assumed the water column in each borehole was under thermodynamic equilibrium with the local geothermal gradient of the subsurface, meaning rocks and aquifers. Most of the acquired results show typical patterns, with the upper part of the log depending on altitude, weather and climate as well as on seasonal temperature changes. For deeper parts, the temperature normally increases depending on the local geothermal gradient. The temperature logs for some boreholes located in urban agglomerations showed anthropogenic influence caused by the presence of infrastructure, the urban heat island effect, post-mining activities, etc. The presented research methods are suitable for applications connected with studies crucial to selecting the locations of geothermal installations and to optimize their technical parameters. The observations also help to identify zones of intensified groundwater flow, groundwater inrush into wells, fractured and fissured zones and many others.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-21
DOI
https://doi.org/10.3390/s24237419
Citations
1
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Borehole Optical Fibre Distributed Temperature Sensing vs. Manual Temperature Logging for Geothermal Condition Assessment: Results of the OptiSGE Project

Maciej R. Kłonowski, Weronika Pratkowiecka, Kirsti Midttømme, Karol Zawistowski et al.
1 citations
Sensors
Seismic Waves and Analysis
0.53
article

Borehole Optical Fibre Distributed Temperature Sensing vs. Manual Temperature Logging for Geothermal Condition Assessment: Results of the OptiSGE Project

Maciej R. Kłonowski, Weronika Pratkowiecka, Kirsti Midttømme, Karol Zawistowski, Peter J. Thomas, Anders Nermoen, Urszula Wyrwalska, Paweł Brytan, Anna Krzonkalla, Agnieszka Ładocha, Adrianna Maćko, Jolanta Duczmańska-Kłonowska
article en
1 citations

Abstract

Geothermal energy is a crucial component contributing to the development of local thermal energy systems as a carbon-neutral and reliable energy source. Insights into its availability derive from knowledge of geology, hydrogeology and the thermal regime of the subsurface. This expertise helps to locate and monitor geothermal installations as well as observe diverse aspects of natural and man-made thermal effects. Temperature measurements were performed in hydrogeological boreholes in south-western Poland using two methods, i.e., manual temperature logging and optical fibre distributed temperature sensing (OF DTS). It was assumed the water column in each borehole was under thermodynamic equilibrium with the local geothermal gradient of the subsurface, meaning rocks and aquifers. Most of the acquired results show typical patterns, with the upper part of the log depending on altitude, weather and climate as well as on seasonal temperature changes. For deeper parts, the temperature normally increases depending on the local geothermal gradient. The temperature logs for some boreholes located in urban agglomerations showed anthropogenic influence caused by the presence of infrastructure, the urban heat island effect, post-mining activities, etc. The presented research methods are suitable for applications connected with studies crucial to selecting the locations of geothermal installations and to optimize their technical parameters. The observations also help to identify zones of intensified groundwater flow, groundwater inrush into wells, fractured and fissured zones and many others.

SensorsVol. 24(23)
NORCE Research AS (NO), Polish Geological Institute (PL)
Sustainable cities and communities
Openalex Percentile: Top 32%
Seismic Waves and Analysis
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.