Eddy Current Measurement of Electrical Resistivity in Heat-Treated Zr-2.5%Nb Pressure Tubes

Zr-2.5%Nb pressure tubes (PTs) house uranium fuel bundles in the fuel channels of CANDU<sup>®</sup> nuclear reactors. Preventing a failure mode caused by contact of the PT with an outer calandria tube (CT) is performed by inspection using eddy current (EC) testing and ultrasonic testing (UT) to measure the PT-CT gap. EC gap measurements are particularly sensitive to circumferential variation of the PT's electrical resistivity due to microstructural variations. A full-factorial experiment was performed to examine the statistical significance of variations in the EC test parameters and manufacturing conditions on the average circumferential electrical resistivity of as-manufactured PTs. It was found that 79% of the variance in the data could be attributed to variations caused by any of the test factors or combinations of test factors. The parameters that accounted for the majority of the variance were: (1) heat treatment (HT); (2) HT and EC frequency; (3) probe inner or outer surface placement; and (4) EC frequency. Measurements of circumferential resistivity showed up to ±2.3% variation from the average of either surface. HT caused the average PT resistivity to decrease at a rate of 1.53±0.08 μΩ·cmlog⁡hr and 1.1±0.4μΩ·cmlog⁡hr for inner and outer PT surfaces, respectively. The results are correlated with differences reported in the literature in the average βZr ribbon thickness in the axial-transverse cross-section between inner and outer PT surfaces. The results demonstrate potential for EC-based resistivity measurements to characterize variations and changes in the microstructure of Zr-2.5%Nb PT material.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-21
DOI
https://doi.org/10.3390/s24237426
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eddy Current Measurement of Electrical Resistivity in Heat-Treated Zr-2.5%Nb Pressure Tubes

Thomas W. Krause, P. R. Underhill, W. Thorpe
Sensors
Nuclear Materials and Properties
article

Eddy Current Measurement of Electrical Resistivity in Heat-Treated Zr-2.5%Nb Pressure Tubes

Thomas W. Krause, P. R. Underhill, W. Thorpe
article en

Abstract

Zr-2.5%Nb pressure tubes (PTs) house uranium fuel bundles in the fuel channels of CANDU<sup>®</sup> nuclear reactors. Preventing a failure mode caused by contact of the PT with an outer calandria tube (CT) is performed by inspection using eddy current (EC) testing and ultrasonic testing (UT) to measure the PT-CT gap. EC gap measurements are particularly sensitive to circumferential variation of the PT's electrical resistivity due to microstructural variations. A full-factorial experiment was performed to examine the statistical significance of variations in the EC test parameters and manufacturing conditions on the average circumferential electrical resistivity of as-manufactured PTs. It was found that 79% of the variance in the data could be attributed to variations caused by any of the test factors or combinations of test factors. The parameters that accounted for the majority of the variance were: (1) heat treatment (HT); (2) HT and EC frequency; (3) probe inner or outer surface placement; and (4) EC frequency. Measurements of circumferential resistivity showed up to ±2.3% variation from the average of either surface. HT caused the average PT resistivity to decrease at a rate of 1.53±0.08 μΩ·cmlog⁡hr and 1.1±0.4μΩ·cmlog⁡hr for inner and outer PT surfaces, respectively. The results are correlated with differences reported in the literature in the average βZr ribbon thickness in the axial-transverse cross-section between inner and outer PT surfaces. The results demonstrate potential for EC-based resistivity measurements to characterize variations and changes in the microstructure of Zr-2.5%Nb PT material.

SensorsVol. 24(23)
Queen's University (CA), Royal Military College of Canada (CA)
University Network of Excellence in Nuclear Engineering, Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 87%
Nuclear Materials and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.