An Experimental Comparison of the Performances of a Small Water-to-Water Heat Pump Working with R1234ze(E) and Its Mixture R515B

The study presents the results of an experimental investigation aimed at evaluating the performance of a water-to-water heat pump utilising R1234ze(E) and R515B in a drop-in application. Several operating conditions are tested, varying the mass flow rates and temperatures of the secondary fluids that pass through the heat exchangers while maintaining the compressor shaft rotational frequency and the vapour superheating at the evaporator outlet constant. Overall, when compared to R1234ze(E), the utilisation of R515B results in capacity and COP variations within −6.81% to +2.46% and −2.41% to +6.29%, respectively. Regarding the performance of the compressor, R515B exhibits comparable volumetric and overall efficiency, while a slightly lower refrigerant temperature at the compressor discharge is found, with differences ranging from −3.1 °C to −0.5 °C. Overall, R515B appears to be more suitable than R1234ze(E) for applications in the high-temperature range.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-21
DOI
https://doi.org/10.3390/en17235812
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Comparison of the Performances of a Small Water-to-Water Heat Pump Working with R1234ze(E) and Its Mixture R515B

Luca Molinaroli, Andrea Lucchini, Luigi Pietro Maria Colombo
Energies
Refrigeration and Air Conditioning Technologies
article

An Experimental Comparison of the Performances of a Small Water-to-Water Heat Pump Working with R1234ze(E) and Its Mixture R515B

Luca Molinaroli, Andrea Lucchini, Luigi Pietro Maria Colombo
article en

Abstract

The study presents the results of an experimental investigation aimed at evaluating the performance of a water-to-water heat pump utilising R1234ze(E) and R515B in a drop-in application. Several operating conditions are tested, varying the mass flow rates and temperatures of the secondary fluids that pass through the heat exchangers while maintaining the compressor shaft rotational frequency and the vapour superheating at the evaporator outlet constant. Overall, when compared to R1234ze(E), the utilisation of R515B results in capacity and COP variations within −6.81% to +2.46% and −2.41% to +6.29%, respectively. Regarding the performance of the compressor, R515B exhibits comparable volumetric and overall efficiency, while a slightly lower refrigerant temperature at the compressor discharge is found, with differences ranging from −3.1 °C to −0.5 °C. Overall, R515B appears to be more suitable than R1234ze(E) for applications in the high-temperature range.

EnergiesVol. 17(23)
Politecnico di Milano (IT)
Clean water and sanitation
Openalex Percentile: Top 79%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.