Proof-of-Concept Quantitative Monitoring of Respiration Using Low-Energy Wearable Piezoelectric Thread

Currently, wearable sensors can measure vital sign frequencies, such as respiration rate, but they fall short of providing quantitative data, such as respiratory tidal volume. Meanwhile, the airflow at the mouth carries both the frequency and quantitative respiratory signals. In this study, we propose a method to calibrate a wearable piezoelectric thread sensor placed on the chest using mouth airflow for accurate quantitative respiration monitoring. Prior to human trials, we introduced an artificial ventilator as a test subject. To validate the proposed concept, we embedded a miniaturized tube airflow sensor at the ventilator’s outlet, which simulates human respiration, and attached a wearable piezoelectric thread to the piston, which moves periodically to mimic human chest movement. The integrated output readings from the wearable sensor aligned with the airflow rate measurements, demonstrating its ability to accurately monitor not only respiration rate but also quantitative metrics such as respiratory volume. Finally, tidal volume measurement was demonstrated using the wearable piezoelectric thread.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-11-21
DOI
https://doi.org/10.3390/electronics13234577
Citations
5
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proof-of-Concept Quantitative Monitoring of Respiration Using Low-Energy Wearable Piezoelectric Thread

Yoshihiro Hasegawa, Mitsuhiro Shikida, Muhammad Salman Al Farisi, Tsutomu Kawabe et al.
5 citations
Electronics
Non-Invasive Vital Sign Monitoring
0.92
article

Proof-of-Concept Quantitative Monitoring of Respiration Using Low-Energy Wearable Piezoelectric Thread

Yoshihiro Hasegawa, Mitsuhiro Shikida, Muhammad Salman Al Farisi, Tsutomu Kawabe, Miyoko Matsushima, Kenta Horie
article en
5 citations

Abstract

Currently, wearable sensors can measure vital sign frequencies, such as respiration rate, but they fall short of providing quantitative data, such as respiratory tidal volume. Meanwhile, the airflow at the mouth carries both the frequency and quantitative respiratory signals. In this study, we propose a method to calibrate a wearable piezoelectric thread sensor placed on the chest using mouth airflow for accurate quantitative respiration monitoring. Prior to human trials, we introduced an artificial ventilator as a test subject. To validate the proposed concept, we embedded a miniaturized tube airflow sensor at the ventilator’s outlet, which simulates human respiration, and attached a wearable piezoelectric thread to the piston, which moves periodically to mimic human chest movement. The integrated output readings from the wearable sensor aligned with the airflow rate measurements, demonstrating its ability to accurately monitor not only respiration rate but also quantitative metrics such as respiratory volume. Finally, tidal volume measurement was demonstrated using the wearable piezoelectric thread.

ElectronicsVol. 13(23)
Hiroshima City University (JP), Nagoya University (JP)
Affordable and clean energy
Openalex Percentile: Top 27%
Non-Invasive Vital Sign Monitoring
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.