Experimental investigation of toe laser intensity effects on capsule compression in indirect-drive inertial confinement fusion

Abstract In indirect-drive inertial confinement fusion (ICF) research, the meticulous design and optimization of laser parameters are crucial for achieving high-gain ignition. The intensity of the toe laser, used for ablating the hohlraum sealing membrane, is a subtle but equally critical parameter. This study introduces a novel experimental approach using the Velocity Interferometer System for Any Reflector (VISAR) to assess the impact of toe laser intensity on the compression of fusion capsules. By tracking the reflectivity of tracer layers and shock velocities in liquid deuterium, the adverse effects of insufficient toe laser intensity on capsule compression have been unveiled for the first time. From a comparison with hydrodynamic simulations, we show that below a critical threshold of 0.23 × 10 14 W cm −2 , the adiabat, a measure of the fuel’s compression efficiency, increases markedly with the toe laser intensity decreases, whereas it remains stable within the range of (0.23 ∼ 7) × 10 14 W cm −2 . Our findings provide critical insights on toe laser parameter design, enhancing our understanding of the role of toe laser intensity in ICF experiments. This research not only refines the parameters for laser operation but also underscores the importance of precision in achieving the desired implosion efficiency, contributing to the development of nuclear fusion as a clean energy source.

Authors

Institutions

Publication Details

Journal
Nuclear Fusion
Published
2024-11-21
DOI
https://doi.org/10.1088/1741-4326/ad948a
Citations
3
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of toe laser intensity effects on capsule compression in indirect-drive inertial confinement fusion

Hao Liu, Yuxue Zhang, Zhebin Wang, Zanyang Guan et al.
3 citations
Nuclear Fusion
Laser-Plasma Interactions and Diagnostics
1.98
article

Experimental investigation of toe laser intensity effects on capsule compression in indirect-drive inertial confinement fusion

Hao Liu, Yuxue Zhang, Zhebin Wang, Zanyang Guan, Longfei Jing, Xiaoxi Duan, Dong Sheng Yang, Huan Zhang, Chen Zhang, Yulong Li, Dong Yunsong, Zhichao Li, Jiamin Yang, Weiming Yang
article en
3 citations

Abstract

Abstract In indirect-drive inertial confinement fusion (ICF) research, the meticulous design and optimization of laser parameters are crucial for achieving high-gain ignition. The intensity of the toe laser, used for ablating the hohlraum sealing membrane, is a subtle but equally critical parameter. This study introduces a novel experimental approach using the Velocity Interferometer System for Any Reflector (VISAR) to assess the impact of toe laser intensity on the compression of fusion capsules. By tracking the reflectivity of tracer layers and shock velocities in liquid deuterium, the adverse effects of insufficient toe laser intensity on capsule compression have been unveiled for the first time. From a comparison with hydrodynamic simulations, we show that below a critical threshold of 0.23 × 10 14 W cm −2 , the adiabat, a measure of the fuel’s compression efficiency, increases markedly with the toe laser intensity decreases, whereas it remains stable within the range of (0.23 ∼ 7) × 10 14 W cm −2 . Our findings provide critical insights on toe laser parameter design, enhancing our understanding of the role of toe laser intensity in ICF experiments. This research not only refines the parameters for laser operation but also underscores the importance of precision in achieving the desired implosion efficiency, contributing to the development of nuclear fusion as a clean energy source.

Nuclear FusionVol. 65(1)
China Academy of Engineering Physics (CN), Chinese Academy of Engineering (CN)
National Natural Science Foundation of China
Industry, innovation and infrastructure
Openalex Percentile: Top 8%
Laser-Plasma Interactions and Diagnostics
1.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.