Behavior of Fiber Reinforced Concrete Beams with Inadequate Torsion Steel under Pure Torsion

To investigate the relationship between reinforced concrete beams under pure torsion and steel fiber usage, 16 large-scaled reinforced concrete beams with inadequate torsion steel were designed and produced. For experiments, a new test setup was designed to allow specimens to have rotational movement on one end and axial movement on the other end. The variables were selected as 300 and 400 mm spacings of transverse reinforcements and 0.0%, 0.3%, 0.6%, 0.9%, 1.2%, and 1.5% by volume of the mixture as steel fiber ratios. Cracking torque, maximum torque and ultimate torque values were obtained experimentally, and torque-twist curves and energy dissipation capacities were determined. Findings were compared to indicate the relationship between variables. Results showed that certain values of steel fiber ratio as a replacement material for relevant spacing of transverse reinforcements.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Civil Engineering
Published
2024-11-21
DOI
https://doi.org/10.18400/tjce.1358643
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior of Fiber Reinforced Concrete Beams with Inadequate Torsion Steel under Pure Torsion

Osman Kaya, Yılmaz Öğünç Tetik
Turkish Journal of Civil Engineering
Structural Behavior of Reinforced Concrete
article

Behavior of Fiber Reinforced Concrete Beams with Inadequate Torsion Steel under Pure Torsion

Osman Kaya, Yılmaz Öğünç Tetik
article en

Abstract

To investigate the relationship between reinforced concrete beams under pure torsion and steel fiber usage, 16 large-scaled reinforced concrete beams with inadequate torsion steel were designed and produced. For experiments, a new test setup was designed to allow specimens to have rotational movement on one end and axial movement on the other end. The variables were selected as 300 and 400 mm spacings of transverse reinforcements and 0.0%, 0.3%, 0.6%, 0.9%, 1.2%, and 1.5% by volume of the mixture as steel fiber ratios. Cracking torque, maximum torque and ultimate torque values were obtained experimentally, and torque-twist curves and energy dissipation capacities were determined. Findings were compared to indicate the relationship between variables. Results showed that certain values of steel fiber ratio as a replacement material for relevant spacing of transverse reinforcements.

Turkish Journal of Civil EngineeringVol. 36(3)
Muğla University (TR)
Sustainable cities and communities
Openalex Percentile: Top 78%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.