A method to get perfect balance point of differential eddy current displacement sensors

Abstract This study introduces a novel method to increase the stability of the balance point in precision differential eddy current sensor (ECS) displacement sensors, which is crucial for achieving optimal performance and improving the interchangeability of sensor probes. The temperature drift coefficient at the electrical balance point (BTC), a common issue affecting the accuracy and reliability of measurements, is addressed through our approach. The BTC can be accurately adjusted by fine-tuning the length of the aluminum target, which aligns the zero-temperature drift position with the electrical balance position, thereby achieving a perfect balance point. The experimental results demonstrate that the proposed method significantly reduces the temperature drift near the balance point of the differential ECS. The BTC was effectively reduced from −7.21 nm/°C to 0.22 nm/°C. This substantial reduction in the BTC enhances the stability of the sensor, facilitating more reliable measurements in high-precision applications.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2024-11-21
DOI
https://doi.org/10.1088/1361-6501/ad9511
Citations
2
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A method to get perfect balance point of differential eddy current displacement sensors

Guangzheng Chen, Shuyu Zhu, Zhi Hua Feng, Tao Xu et al.
2 citations
Measurement Science and Technology
Non-Destructive Testing Techniques
0.43
article

A method to get perfect balance point of differential eddy current displacement sensors

Guangzheng Chen, Shuyu Zhu, Zhi Hua Feng, Tao Xu, Jing Yin
article en
2 citations

Abstract

Abstract This study introduces a novel method to increase the stability of the balance point in precision differential eddy current sensor (ECS) displacement sensors, which is crucial for achieving optimal performance and improving the interchangeability of sensor probes. The temperature drift coefficient at the electrical balance point (BTC), a common issue affecting the accuracy and reliability of measurements, is addressed through our approach. The BTC can be accurately adjusted by fine-tuning the length of the aluminum target, which aligns the zero-temperature drift position with the electrical balance position, thereby achieving a perfect balance point. The experimental results demonstrate that the proposed method significantly reduces the temperature drift near the balance point of the differential ECS. The BTC was effectively reduced from −7.21 nm/°C to 0.22 nm/°C. This substantial reduction in the BTC enhances the stability of the sensor, facilitating more reliable measurements in high-precision applications.

Measurement Science and TechnologyVol. 36(1)
University of Science and Technology of China (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 41%
Non-Destructive Testing Techniques
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.