Statistical biases correction in channelized Hotelling model observers

<i>Objective.</i>Channelized Hotelling model observers are efficient at simulating the human observer visual performance in medical imaging detection tasks. However, channelized Hotelling observers (CHO) are subject to statistical biases from zero-signal and finite-sample effects. The point estimate of the<i>d'</i>value is also not always symmetric with exact confidence interval (CI) bounds determined for the infinitely trained CHO. A method for correcting these statistical biases and CI asymmetry is studied.<i>Approach.</i>CHO<i>d'</i>values and CI bounds with hold-out and resubstitution methods were computed for a range of 200 × 200 pixels images from 20 to 10 000 images for 10, 40 and 96 channels from a set of 20 000 images with gaussian coloured simulated noise and simulated signal. The median of the non-central<i>F</i>cumulative distribution (<i>F'</i>), which is the CHO underlying statistical behaviour for the resubstitution method, was computed, and compared to<i>d'</i>values and CI bounds. A set of experimental data was used to evaluate<i>F'</i>median values.<i>Main results.</i>The<i>F'</i>median allows to get accurate corrected simulated<i>d'</i>values down to zero-signals. For small<i>d'</i>values, the variation of<i>d'</i>values with the inverse of number of images is not linear while the<i>F'</i>median allows a good correction in such conditions. The<i>F'</i>median is also inherently symmetric with regards to the CI. With experimental data,<i>F'</i>median values in a range of about 1-10<i>d'</i>values were within -0.8% to 4.7% of linearly extrapolated values at an infinite number of images.<i>Significance.</i>The<i>F'</i>median correction is an effective simultaneous correction of the zero-signal statistical bias and finite-sample statistical bias, and of CI asymmetry of CHO.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-11-21
DOI
https://doi.org/10.1088/1361-6560/ad9541
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Statistical biases correction in channelized Hotelling model observers

L. Desponds
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

Statistical biases correction in channelized Hotelling model observers

L. Desponds
article en

Abstract

<i>Objective.</i>Channelized Hotelling model observers are efficient at simulating the human observer visual performance in medical imaging detection tasks. However, channelized Hotelling observers (CHO) are subject to statistical biases from zero-signal and finite-sample effects. The point estimate of the<i>d'</i>value is also not always symmetric with exact confidence interval (CI) bounds determined for the infinitely trained CHO. A method for correcting these statistical biases and CI asymmetry is studied.<i>Approach.</i>CHO<i>d'</i>values and CI bounds with hold-out and resubstitution methods were computed for a range of 200 × 200 pixels images from 20 to 10 000 images for 10, 40 and 96 channels from a set of 20 000 images with gaussian coloured simulated noise and simulated signal. The median of the non-central<i>F</i>cumulative distribution (<i>F'</i>), which is the CHO underlying statistical behaviour for the resubstitution method, was computed, and compared to<i>d'</i>values and CI bounds. A set of experimental data was used to evaluate<i>F'</i>median values.<i>Main results.</i>The<i>F'</i>median allows to get accurate corrected simulated<i>d'</i>values down to zero-signals. For small<i>d'</i>values, the variation of<i>d'</i>values with the inverse of number of images is not linear while the<i>F'</i>median allows a good correction in such conditions. The<i>F'</i>median is also inherently symmetric with regards to the CI. With experimental data,<i>F'</i>median values in a range of about 1-10<i>d'</i>values were within -0.8% to 4.7% of linearly extrapolated values at an infinite number of images.<i>Significance.</i>The<i>F'</i>median correction is an effective simultaneous correction of the zero-signal statistical bias and finite-sample statistical bias, and of CI asymmetry of CHO.

Physics in Medicine and BiologyVol. 69(23)
General Electric (Spain) (ES), Guided Therapeutics (United States) (US)
Openalex Percentile: Top 65%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Statistical biases correction in channelized Hotelling model observers — L. Desponds · Physics in Medicine and Biology (2024) | TGRS Research Map | TGRS