Flexible Organic X‐Ray Sensors: Solving the Key Constraints of PET Substrates

Abstract Organic semiconductor‐based sensors are a unique class of wearable x‐ray detectors, as the response from their carbon‐based composition can mimic the response of the human body to radiation. A thin (260 nm) flexible P3HT: o‐IDTBR‐based organic sensor, deposited onto a conductive Kapton substrate is demonstrated, can provide precise and artifact‐free dosimetry under synchrotron x‐rays with sensitivities of (1958 ± 31)pCGy −1 cm −2 without bias. The sensor is capable of accurately resolving multiple 50 µm‐wide x‐rays with a full‐width‐half‐max of (51.6 ± 1.9)µm for a range of energies (47–87.5)keV and dose‐rates (0.21–0.45)kGy s −1 . Organic sensors fabricated with plastic polyethylene substrates exhibit unreliable x‐ray responses and broadening of the full‐width‐half‐max. Simulations reveal that x‐ray induced electrostatic charge generated from the polyethylene causes a reverse polarity of the signal. X‐ray charge mapping shows the effective area sensitized with the polyethylene device extends twice the length of the pixel area, while sensors with Kapton substrates closely match the expected active area. Radiation tolerance of P3HT:o‐IDTBR devices maintain 85.4% of the initial x‐ray sensitivity after 10 kGy with similar radiation tolerances to amorphous silicon. This study confirms the unsuitability of polyethylene substrates for flexible radiation detectors, providing the first evidence of the quantitative and spatial resolution limitations created by the generation of radiation‐induced charge.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2024-11-21
DOI
https://doi.org/10.1002/adfm.202415723
Citations
11
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
2.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Organic X‐Ray Sensors: Solving the Key Constraints of PET Substrates

David Bolst, Bronson W. Philippa, Attila J. Mozer, Marco Petasecca et al.
11 citations
Advanced Functional Materials
Radiation Effects in Electronics
2.30
article

Flexible Organic X‐Ray Sensors: Solving the Key Constraints of PET Substrates

David Bolst, Bronson W. Philippa, Attila J. Mozer, Marco Petasecca, Susanna Guatelli, Matthew J. Griffith, Jessie A. Posar, Laurance Papale, Matthew Large, Aishah Bashiri, Chris Hall
article en
11 citations

Abstract

Abstract Organic semiconductor‐based sensors are a unique class of wearable x‐ray detectors, as the response from their carbon‐based composition can mimic the response of the human body to radiation. A thin (260 nm) flexible P3HT: o‐IDTBR‐based organic sensor, deposited onto a conductive Kapton substrate is demonstrated, can provide precise and artifact‐free dosimetry under synchrotron x‐rays with sensitivities of (1958 ± 31)pCGy −1 cm −2 without bias. The sensor is capable of accurately resolving multiple 50 µm‐wide x‐rays with a full‐width‐half‐max of (51.6 ± 1.9)µm for a range of energies (47–87.5)keV and dose‐rates (0.21–0.45)kGy s −1 . Organic sensors fabricated with plastic polyethylene substrates exhibit unreliable x‐ray responses and broadening of the full‐width‐half‐max. Simulations reveal that x‐ray induced electrostatic charge generated from the polyethylene causes a reverse polarity of the signal. X‐ray charge mapping shows the effective area sensitized with the polyethylene device extends twice the length of the pixel area, while sensors with Kapton substrates closely match the expected active area. Radiation tolerance of P3HT:o‐IDTBR devices maintain 85.4% of the initial x‐ray sensitivity after 10 kGy with similar radiation tolerances to amorphous silicon. This study confirms the unsuitability of polyethylene substrates for flexible radiation detectors, providing the first evidence of the quantitative and spatial resolution limitations created by the generation of radiation‐induced charge.

Advanced Functional MaterialsVol. 35(8)
University of South Australia (AU), University of Wollongong (AU), Australian Synchrotron (AU), Najran University (SA), James Cook University (AU)
Australian Institute of Nuclear Science and Engineering, Office of National Intelligence
Openalex Percentile: Top 11%
Radiation Effects in Electronics
2.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.