Comparative Analysis of Real-World Clinical Outcomes of a Novel Pulsed Field Ablation System for Pulmonary Vein Isolation: The Prospective CIRCLE-PVI Study

<b>Background:</b> Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting. <b>Methods</b>: This prospective, single-center study enrolled 125 consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with PFA at Ulm University Heart Center. Twenty-five patients underwent PFA PVI using a novel PFA system (PulseSelect<sup>TM</sup>, Medtronic, Dublin, Ireland) which incorporates a new circular catheter design and additional features such as ECG-triggered energy application and phrenic nerve capture testing. In comparison, 100 patients were treated using the established PFA system (Farapulse<sup>TM</sup>, Boston Scientific, Marlborough, MA, USA). <b>Results</b>: Acute PVI was achieved in 100% of the patients. Procedure duration, total left atrial (LA) time and fluoroscopy time remained comparable between both groups. The total number of energy deliveries was higher with the novel circular PFA catheter (34.0 vs. 32.0; <i>p</i> < 0.001). No procedure-related complications, including pericardial tamponade, phrenic nerve injury, atrial-esophageal fistula, vascular complications, embolisms, malignant cardiac arrhythmias, or coronary spasms were observed. <b>Conclusions</b>: The novel and the established PFA systems demonstrated comparable results in terms of procedure duration, fluoroscopy time, and LA time. In the hands of experienced operators, the novel circular PFA system enables an effective, consistent, and safe approach to successful PFA PVI.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-11-21
DOI
https://doi.org/10.3390/jcm13237040
Citations
4
Primary Topic
Microbial Inactivation Methods
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Real-World Clinical Outcomes of a Novel Pulsed Field Ablation System for Pulmonary Vein Isolation: The Prospective CIRCLE-PVI Study

Wolfgang Rottbauer, Karolina Weinmann, Carlo Bothner, Yannick Teumer et al.
4 citations
Journal of Clinical Medicine
Microbial Inactivation Methods
1.55
article

Comparative Analysis of Real-World Clinical Outcomes of a Novel Pulsed Field Ablation System for Pulmonary Vein Isolation: The Prospective CIRCLE-PVI Study

Wolfgang Rottbauer, Karolina Weinmann, Carlo Bothner, Yannick Teumer, Lyuboslav Katov
article en
4 citations

Abstract

<b>Background:</b> Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting. <b>Methods</b>: This prospective, single-center study enrolled 125 consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with PFA at Ulm University Heart Center. Twenty-five patients underwent PFA PVI using a novel PFA system (PulseSelect<sup>TM</sup>, Medtronic, Dublin, Ireland) which incorporates a new circular catheter design and additional features such as ECG-triggered energy application and phrenic nerve capture testing. In comparison, 100 patients were treated using the established PFA system (Farapulse<sup>TM</sup>, Boston Scientific, Marlborough, MA, USA). <b>Results</b>: Acute PVI was achieved in 100% of the patients. Procedure duration, total left atrial (LA) time and fluoroscopy time remained comparable between both groups. The total number of energy deliveries was higher with the novel circular PFA catheter (34.0 vs. 32.0; <i>p</i> < 0.001). No procedure-related complications, including pericardial tamponade, phrenic nerve injury, atrial-esophageal fistula, vascular complications, embolisms, malignant cardiac arrhythmias, or coronary spasms were observed. <b>Conclusions</b>: The novel and the established PFA systems demonstrated comparable results in terms of procedure duration, fluoroscopy time, and LA time. In the hands of experienced operators, the novel circular PFA system enables an effective, consistent, and safe approach to successful PFA PVI.

Journal of Clinical MedicineVol. 13(23)
Universität Ulm (DE)
Affordable and clean energy
Openalex Percentile: Top 17%
Microbial Inactivation Methods
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.