Energy Saving for Impinging Jet Ventilation System by Employing Various Supply Duct Locations and Return Grill Elevation

The study of energy savings in ventilation systems within buildings is crucial. Impinging jet ventilation (IJV) systems have garnered significant interest from researchers. The identification of the appropriate location for the IJV reveals a gap in the existing literature. This research was conducted to address the existing gap by examining the impact of IJV location on energy savings and thermal comfort. A comprehensive three-dimensional CFD model is examined to accurately simulate the real environment of an office room (3 × 3 × 2.9 m3) during cooling mode, without the application of symmetrical plans. Four locations have been selected: two at the corners and two along the midwalls, designated for fixed-person positions. The return vent height is analyzed utilizing seven measurements: 2.9, 2.6, 2.3, 1.7, 1.1, 0.8, and 0.5 m. The RNG k–ε turbulence model is implemented alongside enhanced wall treatment. The findings indicated that the optimal range for the return vent height is between 1.7 and 0.8 m. It is advisable to utilize the IJV midwall 1 location, positioned behind the seated individual and away from the exterior hot wall. It is characterized by low vortex formation in the local working zone that contributes to a more comfortable sensation while providing recognized energy-saving potential.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-21
DOI
https://doi.org/10.3390/buildings14123716
Citations
5
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy Saving for Impinging Jet Ventilation System by Employing Various Supply Duct Locations and Return Grill Elevation

Mohamed A. Karali, Hassanein Abdelmohsen Refaey, K.M. Almohammadi, Eslam Hussein et al.
5 citations
Buildings
Fire Detection and Safety Systems
1.82
article

Energy Saving for Impinging Jet Ventilation System by Employing Various Supply Duct Locations and Return Grill Elevation

Mohamed A. Karali, Hassanein Abdelmohsen Refaey, K.M. Almohammadi, Eslam Hussein, Bandar Awadh Almohammadi
article en
5 citations

Abstract

The study of energy savings in ventilation systems within buildings is crucial. Impinging jet ventilation (IJV) systems have garnered significant interest from researchers. The identification of the appropriate location for the IJV reveals a gap in the existing literature. This research was conducted to address the existing gap by examining the impact of IJV location on energy savings and thermal comfort. A comprehensive three-dimensional CFD model is examined to accurately simulate the real environment of an office room (3 × 3 × 2.9 m3) during cooling mode, without the application of symmetrical plans. Four locations have been selected: two at the corners and two along the midwalls, designated for fixed-person positions. The return vent height is analyzed utilizing seven measurements: 2.9, 2.6, 2.3, 1.7, 1.1, 0.8, and 0.5 m. The RNG k–ε turbulence model is implemented alongside enhanced wall treatment. The findings indicated that the optimal range for the return vent height is between 1.7 and 0.8 m. It is advisable to utilize the IJV midwall 1 location, positioned behind the seated individual and away from the exterior hot wall. It is characterized by low vortex formation in the local working zone that contributes to a more comfortable sensation while providing recognized energy-saving potential.

BuildingsVol. 14(12)
Yanbu University College (SA), Future University in Egypt (EG), Benha University (EG), Taibah University (SA)
Affordable and clean energy
Openalex Percentile: Top 15%
Fire Detection and Safety Systems
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.