Effects of Waste Glass Bottle Nanoparticles and High Volume of Waste Ceramic Tiles on Concrete Performance When Exposed to Elevated Temperatures: Experimental and Theoretical Evaluations

This article reports the durability performance of modified concrete with silica nanoparticles and a high volume of waste ceramic tiles under varying elevated temperatures. Ordinary Portland cement (OPC) was replaced with 60% waste ceramic tiles powder (WTCPs) and supplemented with 2, 4, 6, 8, and 10% nanopowders from waste glass bottles (WGBNPs) as a rich source of silica. The natural aggregates (both coarse and fine) were fully replaced by the crushed waste ceramic tiles (WTCAs). After 28 days of curing, the modified specimens were exposed to varying elevated temperatures (200, 400, 600, and 800 °C) in a furnace followed by air cooling. Tests such as residual compressive strength, weight loss, ultrasonic plus velocity, visual appearance, and microstructural analysis were conducted. Additionally, analysis of variance (ANOVA) was used to validate the performance of the proposed predictive equations, as well as their terms, using p-values and F-values. It was discerned that OPC substitution with WTCPs and WGBNPs significantly improved the concrete’s performance under elevated temperatures. It is observed that the addition of 2, 4, 6, 8, and 10% WGBNPs lowered the concrete deterioration by increasing the residual strength and reducing both internal and external cracks. This study provides some new insights into the utilization of WTCPs and WGBNPs to produce sustainable and eco-friendly modified concrete with high spalling resistance characteristics at elevated temperatures.

Authors

Institutions

Publication Details

Journal
Fire
Published
2024-11-21
DOI
https://doi.org/10.3390/fire7120426
Citations
12
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
3.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Waste Glass Bottle Nanoparticles and High Volume of Waste Ceramic Tiles on Concrete Performance When Exposed to Elevated Temperatures: Experimental and Theoretical Evaluations

Teng Xiong, Zahraa Hussein Joudah, Riyadh Alsultani, Nur Hafizah A. Khalid et al.
12 citations
Fire
Fire effects on concrete materials
3.13
article

Effects of Waste Glass Bottle Nanoparticles and High Volume of Waste Ceramic Tiles on Concrete Performance When Exposed to Elevated Temperatures: Experimental and Theoretical Evaluations

Teng Xiong, Zahraa Hussein Joudah, Riyadh Alsultani, Nur Hafizah A. Khalid, Ghasan Fahim Huseien, Hassan Amer Algaifi, Akram M. Mhaya
article en
12 citations

Abstract

This article reports the durability performance of modified concrete with silica nanoparticles and a high volume of waste ceramic tiles under varying elevated temperatures. Ordinary Portland cement (OPC) was replaced with 60% waste ceramic tiles powder (WTCPs) and supplemented with 2, 4, 6, 8, and 10% nanopowders from waste glass bottles (WGBNPs) as a rich source of silica. The natural aggregates (both coarse and fine) were fully replaced by the crushed waste ceramic tiles (WTCAs). After 28 days of curing, the modified specimens were exposed to varying elevated temperatures (200, 400, 600, and 800 °C) in a furnace followed by air cooling. Tests such as residual compressive strength, weight loss, ultrasonic plus velocity, visual appearance, and microstructural analysis were conducted. Additionally, analysis of variance (ANOVA) was used to validate the performance of the proposed predictive equations, as well as their terms, using p-values and F-values. It was discerned that OPC substitution with WTCPs and WGBNPs significantly improved the concrete’s performance under elevated temperatures. It is observed that the addition of 2, 4, 6, 8, and 10% WGBNPs lowered the concrete deterioration by increasing the residual strength and reducing both internal and external cracks. This study provides some new insights into the utilization of WTCPs and WGBNPs to produce sustainable and eco-friendly modified concrete with high spalling resistance characteristics at elevated temperatures.

FireVol. 7(12)
National University of Singapore (SG), Chinese Academy of Sciences (CN), Alsalam University College (IQ), UNSW Sydney (AU), University of Misan (IQ), Guangzhou Institute of Energy Conversion (CN), Al-Mustaqbal University, University of Technology Malaysia (MY), Universiti Tenaga Nasional (MY), Tun Hussein Onn University of Malaysia (MY)
Responsible consumption and production
Openalex Percentile: Top 8%
Fire effects on concrete materials
3.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.