Reliability and minimal detectable change of the MX3 hydration testing system

Assessing hydration status outside of laboratories can be challenging given that most hydration measures are invasive, stationary, costly, or have questionable validity. This study investigated the within-day, test-retest reliability, and minimal detectable change (MDC) of the MX3 Hydration Testing System (MX3 Diagnostics), a relatively low cost, noninvasive, and portable method to measure saliva osmolality. Seventy-five adults (44 men, 31 women; 29.6±10.8 yr, 171.1±9.2 cm, 79.1±15.4 kg) presented two saliva samples approximately 3 to 5 minutes apart. Fluid intake was avoided for at least 5 minutes prior to sample collections. For each sample collection, a researcher used the MX3 to tap the tip of a test strip to saliva on a participant's tongue. Intra-class correlation coefficients (ICCs) and MDC were calculated as measures of reliability. Means for the two measurements were 64.3±19.0 mOsm and 65.5±17.9 mOsm (mean difference of -1.2±13.0 mOsm; t = -0.806, p = 0.423). Further analysis with a two-one-sided test procedure revealed equivalence between the two SOSM measurements (p < 0.001 for upper and lower bounds). Within-day repeat measures yielded an ICC of 0.75 and an MDC at the 90% confidence level of 21.3 mOsm. With moderate-to-good reliability, the MX3 appears to be a practical choice for reliably measuring moderate-sized changes (>20 mOsm) in saliva osmolality outside of laboratory constraints.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-11-21
DOI
https://doi.org/10.1371/journal.pone.0313320
Citations
5
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability and minimal detectable change of the MX3 hydration testing system

Ian M. Winter, Patrick B. Wilson, Josie Burdin
5 citations
PLoS ONE
Thermoregulation and physiological responses
1.63
article

Reliability and minimal detectable change of the MX3 hydration testing system

Ian M. Winter, Patrick B. Wilson, Josie Burdin
article en
5 citations

Abstract

Assessing hydration status outside of laboratories can be challenging given that most hydration measures are invasive, stationary, costly, or have questionable validity. This study investigated the within-day, test-retest reliability, and minimal detectable change (MDC) of the MX3 Hydration Testing System (MX3 Diagnostics), a relatively low cost, noninvasive, and portable method to measure saliva osmolality. Seventy-five adults (44 men, 31 women; 29.6±10.8 yr, 171.1±9.2 cm, 79.1±15.4 kg) presented two saliva samples approximately 3 to 5 minutes apart. Fluid intake was avoided for at least 5 minutes prior to sample collections. For each sample collection, a researcher used the MX3 to tap the tip of a test strip to saliva on a participant's tongue. Intra-class correlation coefficients (ICCs) and MDC were calculated as measures of reliability. Means for the two measurements were 64.3±19.0 mOsm and 65.5±17.9 mOsm (mean difference of -1.2±13.0 mOsm; t = -0.806, p = 0.423). Further analysis with a two-one-sided test procedure revealed equivalence between the two SOSM measurements (p < 0.001 for upper and lower bounds). Within-day repeat measures yielded an ICC of 0.75 and an MDC at the 90% confidence level of 21.3 mOsm. With moderate-to-good reliability, the MX3 appears to be a practical choice for reliably measuring moderate-sized changes (>20 mOsm) in saliva osmolality outside of laboratory constraints.

PLoS ONEVol. 19(11)
Old Dominion University (US)
Openalex Percentile: Top 15%
Thermoregulation and physiological responses
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.