Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer

Background Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy. NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration. However, its accuracy is unclear. This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions. Methodology This study included 96 consecutive patients (77 women, 19 men) who underwent primary cementless THA using either a portable navigation system in the lateral position with the flip technique or a cup goniometer in the supine or lateral positions. The average age of the patients was 66.8 years (range = 29-91) and the average body mass index was 24.6 kg/m<sup>2</sup> (range = 17.5-39.9). The accuracy of cup orientation was compared among the three groups. Results The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.1 ± 1.7°, 2.0 ± 1.4°) were smaller than that with the cup goniometer in the supine (3.4 ± 2.4°, 3.4 ± 2.2°) and lateral decubitus positions (3.4 ± 2.5°, 5.0 ± 3.5°). Overall, 91%, 64.5%, and 56.3% were within 5° of the target angles in the navigation, supine goniometer, and lateral goniometer groups, respectively. Conclusions The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-11-21
DOI
https://doi.org/10.7759/cureus.74176
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer

Yasutaka Masada, Toshifumi Ozaki, Tomonori Tetsunaga, Yuki Okazaki et al.
1 links
Cureus
Orthopaedic implants and arthroplasty
article

Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer

Yasutaka Masada, Toshifumi Ozaki, Tomonori Tetsunaga, Yuki Okazaki, Ryuichiro Okuda, Tomohiro Inoue, Sho Muguruma, Kazuki Yamada, Tomoko Tetsunaga, Takashi Koura
article en

Abstract

Background Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy. NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration. However, its accuracy is unclear. This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions. Methodology This study included 96 consecutive patients (77 women, 19 men) who underwent primary cementless THA using either a portable navigation system in the lateral position with the flip technique or a cup goniometer in the supine or lateral positions. The average age of the patients was 66.8 years (range = 29-91) and the average body mass index was 24.6 kg/m<sup>2</sup> (range = 17.5-39.9). The accuracy of cup orientation was compared among the three groups. Results The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.1 ± 1.7°, 2.0 ± 1.4°) were smaller than that with the cup goniometer in the supine (3.4 ± 2.4°, 3.4 ± 2.2°) and lateral decubitus positions (3.4 ± 2.5°, 5.0 ± 3.5°). Overall, 91%, 64.5%, and 56.3% were within 5° of the target angles in the navigation, supine goniometer, and lateral goniometer groups, respectively. Conclusions The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions.

CureusVol. 16(11)
Okayama University (JP), Okayama University Hospital (JP), Okayama Medical Center (JP)
Openalex Percentile: Top 60%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.